Leave Your Message

Malo Ocheperako Omwe Angagwiritsidwe Ntchito M'mafakitale

Mayankho Ogawa Mphamvu Ogwira Ntchito Kwambiri

Siteshoni yaying'ono ndi njira yatsopano komanso yosungira malo yopangidwira kukonza kugawa kwa magetsi m'mizinda, mafakitale, ndi madera akutali. Pophatikiza zigawo zazikulu monga ma transformer, switchgear, ndi machitidwe oteteza ku dongosolo limodzi, malo ocheperako awa amapereka mphamvu yodalirika komanso yogwira ntchito bwino komanso yochepa kwambiri. Yopangidwa kuti ikwaniritse miyezo yapadziko lonse lapansi (IEC, IEEE), malo athu ocheperako amaphatikiza chitetezo, magwiridwe antchito, komanso kusinthasintha kwa ntchito zosiyanasiyana.

    Makhalidwe ndi Mapindu Aakulu

    Kapangidwe Kogwiritsa Ntchito Malo Moyenera​
    Kapangidwe ka modular kamachepetsa kukula kwa malo ndi 60% poyerekeza ndi malo osinthira magetsi akale, zomwe zimapangitsa kuti kuyikako kukhale kotheka m'malo ochepa monga m'makonde a m'mizinda, m'mafakitale, kapena m'madera akutali. Mayunitsi okonzedwa kale amachepetsa nthawi yomanga pamalopo.
    paKuchita Bwino Kwambiri & Kudalirika​
    Pokhala ndi ma transformer oviikidwa mu mafuta kapena ouma, ma vacuum circuit breakers, ndi SF6 gas-insulated switchgear (GIS), ma substation awa amaonetsetsa kuti magetsi akuyenda bwino (11kV mpaka 33kV) komanso amatetezedwa ku zolakwika. Makina olimba oteteza kutentha ndi kuziziritsa amawonjezera kulimba m'nyengo yozizira.
    paSmart Automation & Monitoring​​
    Makina osankha omwe amagwiritsa ntchito IoT amapereka deta yeniyeni pa mphamvu yamagetsi, mphamvu yamagetsi, kutentha, ndi kuzindikira zolakwika. Mphamvu zowongolera kutali kudzera pa SCADA zimagwirizanitsidwa ndi maukonde anzeru a gridi, zomwe zimathandiza kukonza zinthu molosera komanso kuchepetsa nthawi yogwira ntchito.
    paKutumiza Mwachangu & Kukula
    Magawo omangidwa ndi kuyesedwa ndi fakitale amatha kuyikidwa m'masiku ochepa, zomwe zimathandizira nthawi ya ntchito. Mapangidwe osinthika amalola kukweza mphamvu (mpaka 50 MVA) popanda kusintha makina onse, zomwe zimathandiza kukula kwa mphamvu kwa nthawi yayitali.
    paYosamalira Chilengedwe Komanso Yotsika Mtengo​
    Kugwiritsa ntchito phokoso lochepa (
    Transformer Yothira Mafuta a Cooper Yokhala ndi Ma Frequency 10001Transformer Yothira Mafuta a Cooper Yokhala ndi Ma Frequency Aakulu 10002Transformer Yothira Mafuta a Cooper Yokhala ndi Ma Frequency Aakulu 10003
    Malo Ocheperako Ogwiritsidwa Ntchito M'mafakitale
    • Malo Ocheperako Ogwiritsidwa Ntchito M'mafakitale
    • Malo Ocheperako Omwe Angagwiritsidwe Ntchito M'mafakitale01
    • Malo Ocheperako Omwe Angagwiritsidwe Ntchito M'mafakitale02
    • Malo Ocheperako Omwe Angagwiritsidwe Ntchito M'mafakitale03
    • Malo Ocheperako Omwe Angagwiritsidwe Ntchito M'mafakitale04
    • Malo Ocheperako Omwe Angagwiritsidwe Ntchito M'mafakitale05
    Transformer Yothira Mafuta a Cooper01

    Mapulogalamu

    Zomangamanga za Mizinda: Malo osungira magetsi a m'mizinda, malo ochitira malonda, ndi mizinda yanzeru.
    Madera a Mafakitale: Mphamvu yokhazikika ya mafakitale opangira zinthu, migodi, ndi malo osungira deta.
    paMadera Akutali: Kutumiza mwachangu m'madera omwe si a gridi yamagetsi kapena omwe masoka amatha kuchitika.
    Mphamvu Zongowonjezedwanso: Kuphatikizana ndi mafamu a dzuwa/mphepo kuti pakhale kulumikizana bwino kwa gridi.

    Mafotokozedwe Aukadaulo

    Ma Voltage Range: 11kV mpaka 33kV (voltage yapakati).
    paKutha: VAT 5 mpaka VAT 50.
    paKuchuluka kwa nthawi: 50Hz/60Hz.
    paKuziziritsa: Kuziziritsa kwa mpweya mwachilengedwe (AN) kapena kukakamizidwa (AF).
    paKutsatira malamulo: Zikalata za IEC 62271, IEEE 1526, ndi ISO 9001/14001.

    Chitsimikizo chadongosolo

    Mayeso okhwima akuphatikizapo mphamvu ya dielectric, kupirira kwafupikitsa magetsi, ndi kuyerekezera kukwera kwa kutentha.
    Yavomerezedwa ndi KEMA, DEKRA, ndi TÜV chifukwa cha chitetezo ndi kudalirika.

    Chifukwa Chiyani Sankhani Ife?

    Ukatswiri wa Zaka 25+: Mapangidwe otsimikizika a kutentha kwambiri, chinyezi, ndi madera omwe amagwedezeka ndi zivomerezi.
    paNtchito Zoyambira Kumapeto: Kapangidwe, kuyika, ndi chithandizo chokonza nthawi yonse ya moyo.
    paNdalama Zosinthasintha: Kubwereka ndi kulipira ndalama mukamagwiritsa ntchito njira zina kuti muzitha kusinthasintha bajeti yanu.

    Mayankho Amakonda

    Kusintha kwa Zachilengedwe: Malo otchingira omwe sakhudzidwa ndi dzimbiri m'madera a m'mphepete mwa nyanja kapena mapangidwe omwe saphulika m'malo opangira mafuta/gasi.
    paMachitidwe Osakanikirana: Kuphatikiza malo osungira mphamvu zongowonjezwdwanso (monga mabanki a batri) a ma gridi osakanizidwa.
    Transformer Yothira Mafuta a Cooper02Transformer Yothira Mafuta a Cooper03Transformer Yothira Mafuta a Cooper04Transformer Yothira Mafuta a Cooper05

    Ubwino wa malonda

    1. Zipangizo Zapakati ndi Kapangidwe ka Kuzungulira​
    Zipangizo Zazikulu​
    Mitundu ya Aloyi ya Amorphous:
    Kutayika kwa chitsulo kochepa kwambiri (70–80% kuposa chitsulo cha silicon) kumachepetsa kuwononga mphamvu, komwe ndikofunikira kwambiri pamapangidwe ang'onoang'ono komanso ogwira ntchito bwino.
    Kuchuluka kwa mpweya wolowera komanso kutsika kwa maginito pafupi ndi zero kumachepetsa phokoso, ndipo ndi bwino kwambiri m'mizinda kapena m'nyumba.
    Chitsulo cha Silicon Chozungulira Chozizira (CRGO):
    Ma lamination odulidwa ndi laser amachepetsa kutayika kwa mphamvu ya eddy, zomwe zimapangitsa kuti magwiridwe antchito azitha kufika pa 98.5% m'malo ochepa.
    Kuchuluka kwa maginito kumathandizira kugwiritsa ntchito mphamvu zochepa zamagetsi (11kV–33kV).
    Kapangidwe ka Winding
    Mafelemu Oziziritsa Oyenda ndi Mafuta:
    Ma winding a foil a mkuwa/aluminiyamu amachepetsa kutuluka kwa madzi ndi mphamvu ya short-circuit. Ma link amafuta ophatikizidwa amathandizira kutayika kwa kutentha m'malo otsekedwa.
    Magawo olumikizana amachepetsa kupsinjika kwa magetsi pakati pa ma turn, ndikuwonjezera kulimba kwa ma short-circuit (mpaka 50 kA zolakwika zosafanana).
    Ma Winding a Litz Wire Okhala ndi Magawo:
    Waya wa Litz wa multi-strand umachepetsa zotsatira za khungu ndi kuyandikira, kuchepetsa kukana kwa AC kuti igwire ntchito pafupipafupi (monga maulalo a HVDC).
    Makonzedwe a Compact Disc/Winding:
    Ma helical kapena ma disc windings amathandizira kugwiritsa ntchito malo bwino, ophatikizidwa ndi insulation yokhazikika kuti athe kupirira mphezi (≥1.2/50 μs).
    2. Makina Otetezera Kutentha​
    Chotetezera Mafuta ndi Pepala:
    Pepala la cellulose lodzazidwa ndi madzi a ester limapereka mphamvu ya dielectric mpaka 300 kV BIL, yoyenera kwambiri pazipinda zazing'ono zokhala ndi mphamvu zambiri.
    Yolimba ku kutentha kwa thupi (−40°C mpaka +140°C) komanso yotulutsa madzi pang'ono.
    ​Epoxy Resin Casting (Mtundu Wouma):
    Kupaka vacuum-pressure impregnation (VPI) yokhala ndi ma epoxy resins a Class H kumatsimikizira kuti moto sungathe kupsa (IEC 60335) komanso kuti chinyezi chisamalowe m'malo otsekedwa.
    Kuteteza Kowonjezereka kwa Nano:
    Ma epoxy odzaza ndi silica amawonjezera kukana kutulutsa madzi pang'ono ndi 40%, zomwe zimapangitsa kuti moyo ukhale wautali m'madera okhala ndi chinyezi kapena oipitsidwa.
    3. Kusamalira Kutentha​
    Kuziziritsa Mpweya kwa Mafuta ndi Zachilengedwe (ONAN):
    Kuziziritsa kosalekeza kudzera mu ma radiator ndi convection yachilengedwe kuti igwire ntchito mosalekeza m'malo opapatiza (monga, mayunitsi a 100kVA–500kVA).
    Kuziziritsa Mpweya Mokakamizidwa (OFAF):
    Mafani olamulidwa ndi kutentha amathandizira kutayikira kwa kutentha, zomwe zimapangitsa kuti mphamvu yodzaza ndi 120% igwire ntchito pazochitika zadzidzidzi.
    Kuwunika kwa Kutentha kwa Smart:
    Masensa a fiber-optic amatsata malo otentha, kuyambitsa ma alarm kapena kusintha kozizira kuti apewe kuwonongeka kwa insulation.
    4. Kapangidwe ndi Chitetezo cha Kapangidwe​
    Kapangidwe ka Modular ndi Koyenera Malo​
    Ma Enclosure Ophatikizidwa:
    Ma enclosure opangidwa kale, okhala ndi ma modular, ma transformer, ndi ma switchgear, amaikidwa pamalo amodzi, zomwe zimachepetsa nthawi yoyika ndi 50%.
    Ma Ratings a IP66/IP67:
    Kutseka kwa hermetic ndi ma gasket a EPDM ndi zida zosapanga dzimbiri kumateteza ku madzi, fumbi, ndi kulowerera kwa makoswe.
    Chithandizo Choletsa Kutupa:
    Zitsulo zomatira kapena aluminiyamu zoviikidwa m'madzi otentha zokhala ndi zokutira za polyurethane zimapewa kuwonongeka kwa UV komanso kukhudzidwa ndi mchere wa m'mphepete mwa nyanja.
    Zinthu Zachitetezo
    Ma Valves Othandizira Kupanikizika:
    Mpweya umatuluka wokha pakagwa mavuto amkati, zomwe zimathandiza kuti pasachitike kuphulika.
    Machitidwe a Matanki a Conservator:
    Zosungira zotsekedwa zimachepetsa kukhudzana kwa mpweya, kuchepetsa kukhuthala kwa mafuta ndi kupangika kwa matope.
    Chitetezo cha Kutupa:
    Zomangira zinki oxide zolumikizidwa (MOA) zimaletsa kusintha kwa mphamvu ya mphezi (≥2.5 kA impulses).
    5. Ntchito Zapamwamba​
    Machitidwe Oyang'anira Mkhalidwe (CMS):
    Masensa ophatikizidwa amatsata kutentha kwa mafuta, kusanthula kwa mpweya wosungunuka (DGA), kuchuluka kwa katundu, ndi kutulutsa pang'ono, zomwe zimathandiza kukonza bwino kudzera mu SCADA.
    Kuphatikiza kwa Smart Grid:
    Kulankhulana kothandizidwa ndi IoT kumathandizira kuwongolera kutali, kulinganiza katundu, komanso mayankho a gridi yodzichiritsa yokha.
    Zatsopano Zosamalira Chilengedwe:
    Mafuta oteteza kutentha omwe ali ndi bio-based (monga ester fluids) omwe amatha kuwonongeka kwambiri (OECD 301B ikugwirizana ndi malamulo) komanso sayaka kwambiri.
    Ntchito Zofunika Kwambiri ndi Zochitika Zamtsogolo​
    Kugawa kwa Mizinda:
    Malo osungira magetsi okhala ndi mayunitsi amphamvu kwambiri (500kVA–1 MVA), malo osungira magetsi obwezerezedwanso, ndi malo ochapira magetsi a EV.
    Kuphatikiza Mphamvu Zobwezerezedwanso:
    Mapangidwe ang'onoang'ono a minda ya mphepo/dzuwa ndi ma hybrid AC/DC microgrids.
    Zotsatira Zamtsogolo:
    Ma Transformers a Solid-State (SSTs): Yambitsani kusintha kwa DC-DC ndi kusinthasintha kwa gridi ya makina ogawa magawo.
    Kudziteteza Kodzichiritsa: Zipangizo za nanocomposite zimakonza zokha zolakwika zazing'ono za dielectric.
    Chidule​
    Ma Compact Substations amachita bwino kwambiri pogwiritsa ntchito ma cores a amorphous omwe amatayika pang'ono, mapangidwe osungira malo, komanso njira zotetezera zambiri. Kuphatikiza kwawo magwiridwe antchito, kukula, komanso kulimba mtima kumawapangitsa kukhala ofunikira kwambiri pama gridi amakono a m'mizinda ndi mafakitale, pomwe zatsopano monga ukadaulo wolimba komanso wowunikira mwanzeru zimayendetsa luntha la gridi komanso kukhazikika.
    Transformer Yothira Mafuta a Cooper06Transformer Yothira Mafuta a Cooper07Transformer Yothira Mafuta a Cooper08Transformer Yothira Mafuta a Cooper09

    Funsani Tsopano!

    Ngati mukufuna kudziwa zambiri zokhudza zinthu zathu kapena mitengo yake, chonde titumizireni imelo yanu ndipo tidzakulumikizani mkati mwa maola 24.

    Leave Your Message