+86 18068001229 01
Transformer Yokwera Pachidutswa Chimodzi—50kVA
Mafotokozedwe Akatundu
Chosinthira cha JZP Transformer cha 50 kVA chokhala ndi gawo limodzi, chili ndi satifiketi yolembedwa pa UL ndipo chimathandizidwa ndi lipoti loyang'anira la CESI. Ndi mphamvu yamagetsi ya 2.4-34.5kV, chosinthirachi chimatsatira miyezo yosiyanasiyana yapadziko lonse lapansi monga ANSI, IEEE, CSA, IEC, ndi DOE, kuonetsetsa kuti chikugwirizana ndi magwiridwe antchito padziko lonse lapansi. Pogwiritsa ntchito zaka 20 zaukadaulo pakupanga ndi kutumiza kunja, gulu la JZP Transformer lili ndi zida zogwirira ntchito zosiyanasiyana, kupereka mayankho osinthika a ma transformer apadera. Pokhala ndi kudzipereka kwakukulu pakukhutitsidwa kwa makasitomala ndi khalidwe labwino, JZP Transformer imapereka zinthu zodalirika, zogwira mtima, komanso zotetezeka kuti zikwaniritse zosowa zapadera za makasitomala padziko lonse lapansi.

Transformer Yokwera Mizere ya 13.8 kV 50 kVA
D-50-13.8/0.12-0.24kV, transformer ya 50 kVA yokhala ndi ndodo, imapangidwa mosamala ndi JZP Transformer, mogwirizana ndi miyezo ya IEEE C57.12.20. Ndi mphamvu ya 50kVA, imagwira ntchito pa 13.8 kV mbali yoyamba ndipo imapereka 120/240V mbali yachiwiri. Transformer ili ndi ma bushing awiri amphamvu kwambiri, ma bushing atatu otsika mphamvu, ndi zomangira ziwiri kuti zigwire bwino ntchito komanso chitetezo.
JZP Transformer imatsimikizira kuti ndi yapamwamba komanso yodalirika pa chipangizo chilichonse. Ma transformerwa adapangidwa kuti akwaniritse zofunikira zapadera za netiweki yogawa magetsi ku Guyana, kuonetsetsa kuti magetsi akupezeka bwino komanso nthawi zonse. Pokhala ndi kudzipereka kwakukulu pakukhutiritsa makasitomala, JZP Transformer imapereka zinthu zabwino kwambiri komanso ntchito yabwino kwambiri kuti ikwaniritse zosowa za kampani ku Guyana.

14.4 kV 50 kVA Single Phase Transformer
D-50-14.4/0.12-0.24 ndi transformer ya 50 kVA yokhala ndi gawo limodzi lokhala ndi pole. Imagwira ntchito pa 24940/14400V (voltage yapamwamba) ndi 120/240V (voltage yotsika) yokhala ndi HV bushing imodzi. Transformeryi ili ndi aluminiyamu yozungulira yomwe imakwaniritsa miyezo ya CSA C2.1 ndi CSA 802.1. Imagwira ntchito pa 60Hz ndipo ndi ya ONAN cooling system. Transformeryi ndi Class A insulation.

16/27.6kV 50 kVA Sitima Yosinthira Gawo Limodzi
D-50-16-27.6kV/347(600Y)V ndi transformer yapadera ya 50 kVA yokhala ndi gawo limodzi, yopangidwira ntchito zapadera. Yogwira ntchito pamlingo wapamwamba wa 16kV ndi 27.6kV, imapereka mphamvu yochepa ya 347(600Y)V.
Yopangidwa ndi kupangidwa ndi JZP Transformer, imatsatira miyezo yokhwima ya CSA C802.1 ndi CSA C2.1, kuonetsetsa kuti ikugwira ntchito bwino komanso kukhala yotetezeka. Transformeryi imapereka njira ziwiri zogwiritsira ntchito mphamvu zambiri: 16,000V ndi 27,600V, zomwe zimapangitsa kuti ikhale yogwiritsidwa ntchito kwambiri pazochitika zosiyanasiyana zogawa mphamvu. Ili ndi bushing yamagetsi amphamvu, bushing ziwiri zamagetsi otsika mphamvu, ndi switch yamagetsi awiri kuti ikhale yosavuta kusankha magetsi.
Mphamvu zapadera za transformer iyi yamagetsi awiri ya 50kVA single-phase zimakwaniritsa zosowa zamagetsi zapadera m'derali, kuonetsetsa kuti magetsi akupezeka modalirika komanso akukwaniritsa miyezo yapamwamba kwambiri yamakampani.

Chosinthira cha 2.4kV 50 kVA cha Gawo Limodzi
D-50-2.4kV/120(240)V ndi transformer ya 50 kVA yokhala ndi ndodo, gawo limodzi, yokhala ndi voltage yayikulu ya 2.4 kV ndi voltage yotsika ya 120V, yopangidwira kasitomala waku Canada. Transformer iliyonse ili ndi bushing imodzi yamagetsi okwera komanso bushing zitatu zamagetsi otsika, zomwe zimapangitsa kuti kulumikizana kukhale koyenera. Ma transformer awa adapangidwa bwino kwambiri, ndipo amakwaniritsa miyezo yolimba ya CSA, kuonetsetsa kuti magwiridwe antchito abwino komanso otetezeka. Ndi kudzipereka kosalekeza kuchita bwino, ma transformer awa adapangidwa kuti akwaniritse zosowa za kasitomala waku Canada, kupereka kugawa mphamvu kodalirika komanso kutsatira malamulo onse ofunikira amakampani.

Funsani Tsopano!
Ngati mukufuna kudziwa zambiri zokhudza zinthu zathu kapena mitengo yake, chonde titumizireni imelo yanu ndipo tidzakulumikizani mkati mwa maola 24.