+86 18068001229 01
Transformer Yokwera pa Pad ya 225 kVA 34.5kV
Mafotokozedwe Akatundu
JZP Transformer ikunyadira kuyambitsa transformer ya 225 kVA 34.5kV yokhala ndi magawo atatu yokhala ndi ma pad, yopangidwira makamaka makina ogawa mafakitale. Yopangidwa pamlingo wapamwamba kwambiri, imatsimikizira kuti magetsi akugwiritsidwa ntchito bwino m'mafakitale osiyanasiyana.
01020304050607
TRANSFORMER YOKWEZERA MAGAWO ATATU
Zinthu Zofunika Kwambiri
Kuchita Bwino & Kupanga Zinthu Mwatsopano
Mapulogalamu Osinthira a 225 kVA
| 225 kVA 34.5kV Zofunikira pa Transformer | |
| MPHAMVU YOVOMEREZEDWA | 225 kVA |
| KUGANIZA VOLTAGE YAPAMWAMBA | 34500DELTA |
| VOTCHE YACHIWIRI | 600GrdY/347 |
| KUFIKA KWAMBIRI | 60Hz |
| GULU LA VEKTOR | Dyn1 |
| Zipangizo Zozungulira | Aluminiyamu |
| KUTAYA KWA MALONDA | ≤2350W |
| Palibe katundu wotayika | ≤650W |
| MPEDANCE VOTCHE | 5.75% |
| KUKWERA | ≤1,500m |
| MTUNDU | ANSI 70 Imvi yopepuka |
| KULEMERA KWA MAFUTA OIPIRA | 1,040 L |
| KULEMERA KONSE | makilogalamu 2,300 |
| 225 kVA 34.5kV Transformer Chalk | |
| CHIKWANGWANI CHOKWERA | ELSP FUSE |
| Chitseko Chokhala ndi Zingwe | CHIKWANGWANI CHA BAYONET |
| BULEKI YA POYIMIRA MAGALIMOTO | KUSINTHA KWA TAPI |
| CHIKUTO CHA THANKANI | CHIYEZO CHA MULINGO WA MAFUTA |
| LV BUSHING (Mabowo 4) | Vavu Yothandizira Kupanikizika |
| CHIPANGIZO CHOTHANDIZA KUPUMULA | CHIYEZO CHA KUPIKITSA KWA VACUUM |
| MALANGIZO A MKUPINDA WA HV | CHOLEMBEDWA CHA TERMINAL |
| CHIZINDIKIRO CHA KUTENTHA | Chogwirira cha chitseko |
| CHITSULO CHA HV BUSHING (35kV) | CHIKWANGWANI CHA MKUWA |
| Chogwirira cha Mkuwa Chopukutira | DZINA LA PLAT |
| SWITCH YA KULUMIKIZANA KWA MIPANGO IWIRI | Mapepala achitsulo chonyowa |
| Vavu yotulutsa madzi ya 1" yokhala ndi chitsanzo cha 3/8" | Zenera la IR |
| VALVU YOFIIRA YA PAMWAMBA YA 1" KULAMBIRA KWA FILTER | BOKISI LA TERMINAL |
Zinthu Zofunika Kwambiri
Zenera la IR (Zenera la Infrared)
Transformer iliyonse ili ndi Mawindo a IR m'zipinda zonse ziwiri zokhala ndi magetsi ambiri komanso otsika, zomwe zimathandiza ogwiritsa ntchito kuchita ma scan a infrared thermal popanda kutsegula zitseko. Kapangidwe kameneka kamatsimikizira kuti amafufuza bwino komanso mosamala, zomwe zimathandiza kuzindikira msanga malo omwe angawotchedwe kapena mavuto okhudzana ndi kutentha kwambiri. Mwa kuzindikira zoopsa monga kudzaza kwambiri, kulumikizana kosasunthika, kapena kukhudzana kosayenera, Window ya IR imawonjezera kukhazikika ndi chitetezo cha transformer.
Zipangizo Zoteteza Zapamwamba
Transformer ya 225 kVA ili ndi njira zosiyanasiyana zotetezera kuti zitsimikizire kuti ntchito yake ndi yotetezeka komanso kuti ikhale nthawi yayitali, kuphatikizapo:
Gauge ya Vacuum Pressure: Ikuphatikizapo ma alarm awiri olumikizirana kuti muwone kuthamanga kwa magazi nthawi yeniyeni, kupereka chenjezo koyambirira la mavuto omwe angakhalepo.
Chipangizo Chothandizira Kupanikizika: Chokhala ndi zolumikizirana, chimayambitsa chizindikiro chamagetsi pakapezeka kupanikizika kosazolowereka, zomwe zimadziwitsa ogwiritsa ntchito kuti achitepo kanthu kofunikira.
Chizindikiro cha Mulingo wa Mafuta: Chili ndi ma alarm awiri omwe amachenjeza makina owunikira ngati mulingo wa mafuta uli wolakwika, zomwe zimathandiza ogwiritsa ntchito kusintha mwachangu mulingo wa mafuta ndikupitiliza kugwira ntchito bwino.
Chizindikiro cha Kutentha kwa Mafuta: Chikuphatikizapo ma alarm contacts awiri—chimodzi cha zizindikiro zochenjeza ndi china cha zizindikiro zoyendera. Ngati kutentha kwa mafuta kupitirira 70°C, makinawo adzapereka chenjezo; ngati kupitirira 105°C, transformer idzagwa yokha, ndipo makina owunikira adzatumiza chizindikiro chosonyeza vuto.
Kapangidwe Kosavuta Kugwiritsa Ntchito & Kuwunika Kwakunja
Ma Gauges Oyikidwa Panja ndi Ma Drain & Sample Valve: Ogwiritsa ntchito amatha kuyesa mafuta otetezera kutentha ndikuyang'ana ma gauges popanda kudziika pa ma bushings okhala ndi mphamvu yamagetsi komanso mphamvu yamagetsi yochepa, zomwe zimapangitsa kuti chitetezo chikhale chotetezeka, chogwira ntchito bwino, komanso chogwirizana ndi malamulo.
Chishango Choteteza Chipangizo Chothandizira Kupanikizika: Chishango chotetezachi chimaletsa kuwonongeka kwakunja, kuyambitsa mwangozi, komanso kusokonezedwa ndi zinthu zachilengedwe, kuonetsetsa kuti chipangizocho chothandizira kupanikizika chikugwira ntchito bwino ndikuchepetsa chiopsezo cha kutuluka kwa mpweya. Chimaletsanso zinthu zodetsa kulowa mu transformer, kusunga ukhondo ndi kukhazikika kwa nthawi yayitali.

Kuchita Bwino & Kupanga Zinthu Mwatsopano
Chosinthira cha 225 kVA chochokera ku JZP Transformer chapangidwa kuti chigogomeze kudalirika ndi chitetezo kwa nthawi yayitali. Ndi mawindo a infrared, makina owunikira anzeru, komanso zowongolera zakunja zosavuta kugwiritsa ntchito, chosinthirachi sichimangowonjezera magwiridwe antchito komanso chimawonjezera chitetezo cha ntchito zosamalira. Zinthuzi zimathandiza ogwiritsa ntchito kuzindikira ndikuthana ndi mavuto omwe angakhalepo mwachangu, kuchepetsa nthawi yogwira ntchito ndikuwonetsetsa kuti ntchitoyo ikuchitika mosalekeza.

Mapulogalamu Osinthira a 225 kVA
Machitidwe ogawa mphamvu zamagetsi m'mafakitale
Mphamvu zamagetsi zamalonda ndi zapakhomo
Malo osinthira mphamvu zongowonjezwdwanso ndi mphamvu
Malo osungira deta ndi zomangamanga zofunika kwambiri
Mphamvu zambiri zomwe zimafunika kwambiri
JZP Transformer—Kutsimikizira Mphamvu Yodalirika Yokwaniritsa Zosowa Zanu
JZP Transformer yadzipereka kupereka mayankho amagetsi apamwamba kwambiri kwa makasitomala padziko lonse lapansi. Kudzera muukadaulo wapamwamba komanso kuwongolera bwino khalidwe, timaonetsetsa kuti magetsi akupezeka bwino komanso odalirika pama projekiti osiyanasiyana amafakitale ndi amalonda. Kaya ndi kukhazikitsa zida, kukonza, kapena kupanga zinthu mwamakonda, timapereka chithandizo chaukadaulo.

Funsani Tsopano!
Ngati mukufuna kudziwa zambiri zokhudza zinthu zathu kapena mitengo yake, chonde titumizireni imelo yanu ndipo tidzakulumikizani mkati mwa maola 24.