Leave Your Message

Chosinthira Mphamvu cha 138kv 132kv

Ma Voltage Ratings Oyambirira: 132kV, 138kV kapena zina
Ma Voltage Yachiwiri: 11/10.5/6.6/6.3kV kapena zina
MALO OGWIRITSA NTCHITO YA HV: ± 8×1.25% kapena ena
Mtundu Wolumikizira: YNd11 kapena ena
Mtundu: chosinthira mafuta choviikidwa mu mafuta

    Mafotokozedwe Akatundu

    138 kV ndi 132 kV Transformer imachokera pa Standard 1. GB 6451 Mafotokozedwe ndi zofunikira zaukadaulo za ma transformer amphamvu oviikidwa mu mafuta;2. Ma Transformer a Mphamvu a IEC 60076;3. Ma Transformer a Mphamvu a AS NZS 60076;4. Ma Transformer a Mphamvu a CSAC88-16;5. ANSI/IEEE C57.12.00 Muyezo wa IEEE wa Zofunikira Zonse za Ma Transformer Oviikidwa Mu Madzi, Mphamvu, ndi Kulamulira;6. Ma Transformer a Mphamvu a GOST R 52719 - Mafotokozedwe Onse; 7. EN60076 Power Transformer;8. Ntchito Zam'deralo Pambuyo Pogulitsa Ku North America South America ndi madera ena zimayankha zosowa zanu mkati mwa maola 24.
    cer
    Zikalata za Transformer za 138 kV 132 kV
    Kapangidwe ndi kupanga ma transformer a JZP 138KV 132KV akukwaniritsa miyezo ya GB 6451, IEC 60076, AS NZS 60076, CSAC88-16, ANSI/IEEE C57.12.00, GOST R 52719, EN60076. Gulu la akatswiri opanga mainjiniya a JZP lili ndi zaka zoposa 10 zokumana nazo pakupanga ma transformer apadziko lonse lapansi. Malinga ndi zosowa zanu komanso zofunikira zaukadaulo, ndikupatseni yankho loyenera kwambiri la transformer.
    Transformer ya 138 kV ndi 132 kV imachokera ku Standard
    1. GB 6451 Mafotokozedwe ndi zofunikira zaukadaulo za ma transformer amagetsi odzazidwa ndi mafuta;
    2. Ma Transformer a IEC 60076 a Mphamvu;
    3. AS NZS 60076 Power Transformers;
    4. CSAC88-16 Zosinthira Mphamvu;
    5. ANSI/IEEE C57.12.00 Muyezo wa IEEE wa Zofunikira Zonse za Kugawa, Mphamvu, ndi Kulamulira Ma Transformers Omwe Amathiridwa Madzi;
    6. GOST R 52719 Power Transformers - Zambiri Zofunikira;
    7. EN60076 Transformer Yamagetsi;
    8. Ntchito Zapafupi Pambuyo Pogulitsa Ku North America South America ndi madera ena zimayankha zosowa zanu mkati mwa maola 24.
    Transformer iliyonse ya 132 kV ndi 138kV ya JZP iyenera kuyesedwa motsatira miyezo yoyesera yoyenera musanachoke ku fakitale. Pambuyo poyesa kulikonse kokwanira, imatumizidwa kwa kasitomala kuti atsimikizire lipoti loyesa transformer. Ikhoza kupakidwa ndi kutumizidwa.
    Zofotokozera za Transformer ya 138kV ndi 132kV

    Chosinthira mphamvu cha OLTC cha Class Three-phase two winding power transformer cha 132kv

    Mphamvu Yoyesedwa

    Mphamvu Yaikulu

    Volti Yotsika

    Kutayika Kopanda Katundu (kw)

    Kutayika kwa katundu (kw)

    Palibe Katundu wamakono (%)

    10MVA

    132 kV

    6.3 kV

    11.8

    51.2

    0.82

    12MVA

    138 kV

    6.6 kV

    13.7

    59.5

    0.82

    15MVA

     

    10.5 kV

    16.3

    73.1

    0.76

    20MVA

     

    11 kV

    19.5

    88.4

    0.76

    25MVA

       

    22.7

    105

    0.69

    30MVA

       

    27.4

    126

    0.69

    37.5MVA

       

    32.9

    148

    0.63

    50MVA

       

    38.9

    184

    0.63

    60MVA

       

    46.4

    221

    0.57

    Chosinthira mphamvu cha NLTC cha Class Three-phase two winding transformer cha 110kv

    Mphamvu Yoyesedwa

    Mphamvu Yaikulu

    Volti Yotsika

    Kutayika Kopanda Katundu (kw)

    Kutayika kwa katundu (kw)

    Palibe Katundu wamakono (%)

    10MVA

    132 kV

    6.3 kV

    11.8

    51.2

    0.64

    12MVA

    138 kV

    6.6 kV

    12.4

    59.5

    0.64

    15MVA

     

    10.5 kV

    15

    73.1

    0.59

    20MVA

     

    11 kV

    17.8

    88.4

    0.59

    25MVA

       

    21

    105

    0.54

    30MVA

       

    25

    126

    0.54

    37.5MVA

       

    29.9

    148

    0.56

    50MVA

       

    35.3

    178.5

    0.52

    60MVA

       

    41.9

    221

    0.48

    Funsani Tsopano!