Transformer Yokwera Pachidutswa Chimodzi—37.5 kVA

Ma Voltage Ratings Oyambirira: 2.4-34.5 kV
Ma Voltage Yachiwiri: 120/240V; 240/480V; 347/600Y; 277v;
MALO OGWIRITSA NTCHITO YA HV: 2280-36225V
Mtundu Wolumikizira: Ii0/Ii6
Mtundu: Zachizolowezi/CSP
ANALI: 30-150kV
Miyezo: IEEE C57.12.20, ANSI C57.12, DOE 2016, CSA C2.1&2.2 &CSA C802.1
Ntchito: Kugawa, Ntchito Zapamwamba

    Mafotokozedwe Akatundu

    JZP ndi kampani yotsogola yopanga ma transformer omwe ali ndi ziphaso za CSA, UL, ndi cUL. Amadziwika bwino popanga ma transformer apamwamba kwambiri a 37.5 kVA omwe ali ndi gawo limodzi omwe amakwaniritsa miyezo yokhwima ya ANSI, CSA, IEEE, DOE, ndi IEC. Ma transformer awa adapangidwa kuti agwirizane ndi ntchito zosiyanasiyana, kuphatikizapo mautumiki, madera akumidzi, ndi makina ogawa magetsi. Ndi kudzipereka kwakukulu ku khalidwe ndi kudalirika, ma transformer a JZP ndi odalirika chifukwa cha magwiridwe antchito abwino komanso magwiridwe antchito, zomwe zimapangitsa kuti akhale chisankho chabwino kwambiri pazosowa zosiyanasiyana zokhudzana ndi magetsi.
    JZP Transformer imapereka transformer yosinthika ya 37.5 kVA yomwe imagwirizana ndi miyezo yosiyanasiyana yapadziko lonse lapansi ndipo imatha kusinthidwa kuti igwirizane ndi zofunikira zosiyanasiyana. Transformers zathu zatumizidwa bwino kumayiko angapo, kuphatikizapo United States, Canada, Panama, Venezuela, ndi Honduras.
    Ndi mphamvu yopangira mayunitsi opitilira 500 pamwezi, timaonetsetsa kuti nthawi yotumizira ikuyenda mwachangu kwa milungu 5-8. Kudzipereka kwathu pakupanga zinthu zabwino kumapitirira kuposa kupanga, chifukwa tili ndi magulu odzipereka okhazikitsa ndi kukonza zinthu pambuyo pogulitsa ku America. Izi zimatsimikizira kuthetsa mavuto mwachangu komanso kuthetsa mavuto aliwonse omwe mungakumane nawo.
    Kaya ndinu kampani yogulitsa zinthu, yogawa transformer, kapena yomanga, mutha kugula transformer ya JZP yokhala ndi gawo limodzi lokhazikika ndi pole molimba mtima, podziwa kuti mukuyika ndalama pa chinthu chodalirika komanso chodalirika. Dziwani momwe JZP Transformer imagwirira ntchito bwino komanso modalirika, yopangidwira zosowa zanu.
    Transformer Yokwera Pachidutswa Chimodzi—37
    Transformer ya 37.5 kVA 13.8 kV
    DL-37.5/13.8/0.24(0.12), ndi transformer yokhala ndi pole imodzi yopangidwa ndi JZP Transformer, yogwiritsidwa ntchito motsatira miyezo ya IEEE ndi muyezo wa DOE 2016 wogwira ntchito bwino. Transformer iyi ili ndi mphamvu ya 37.5kVA, yokhala ndi mphamvu yamagetsi ya 13800V komanso mphamvu yamagetsi yamagetsi ya 240 (120) V. Njira yake yolumikizira ndi Ii0, yokhala ndi kapangidwe ka polarity kakang'ono.
    DL-37.5/13.8/0.24(0.12) yopangidwira makasitomala aku America, imapereka magwiridwe antchito abwino komanso kudalirika. Ndi luso la JZP pakupanga ndi kupanga ma transformer, mutha kudalira transformer kuti ikwaniritse zosowa zanu moyenera.
    37
    Chosinthira cha 37.5 kVA 14.4 kV
    DL-37.5/14/0.347, ndi transformer yokhala ndi gawo limodzi. Transformer iyi ikutsatira miyezo ya IEEE ndipo ili ndi mphamvu ya 37.5 kVA. Imabwera ndi bushing yamagetsi amphamvu, bushing ziwiri zamagetsi otsika mphamvu, ndi chosinthira chamagetsi cha malo asanu, zomwe zimatsimikizira kuti imagwira ntchito mosiyanasiyana komanso moyenera.
    37
    37.5 kVA 19.9 kV Transformer
    DL-37.5/19.9/0.24(0.12), ndi transformer yopangidwa ndi pole munted. Ndi mphamvu yamagetsi ya 19920V, imakhala ndi ma bushing awiri amphamvu komanso ma bushing atatu amphamvu, zomwe zimathandiza kuti magetsi azigawika mosavuta.
    Transformer yokongola iyi yozungulira yapangidwa mwaluso kwambiri kuti igwire bwino ntchito komanso ikhale yodalirika. Ndi transformer yozungulira ya 37.5kVA yopangidwa kuti ikwaniritse muyezo wolimba wa ANSI C57.12, yotsimikizira magwiridwe antchito abwino komanso chitetezo.