Leave Your Message

Transformer Yokwera Magawo Atatu ya 2500kVA

Ma Voltage Ratings Oyambirira: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2 kapena ena
Ma Voltage Yachiwiri: 208GrdY/120;416GrdY/240,480GrdY/277,/600GrdY/347,220y/127,480V,415v,600v kapena ena
MALO OGWIRITSA NTCHITO YA HV: ± 2×2.5% kapena ena
Mtundu Wolumikizira: Dyn11/YNyn0 kapena ena
Mtundu: Chakudya chozungulira/Chozungulira
ANALI: 30/150 kV
Miyezo: IEEE, CSA, DOE
Ntchito: BESS, migodi ya Crypto, Makampani, Mphamvu ya Mphepo ndi Dzuwa, Kuchajitsa Ma EV
 Kuyesa Mphamvu: 2500 kVA, 2550 kVA, 2.5 MVA
Satifiketi: UL, CUL, CSA, SGS

    Mafotokozedwe Akatundu

    JZP Transformer ndi katswiri wopanga ma transformer okhala ndi mndandanda wa UL ndi ziphaso za milingo yamagetsi mpaka 44kV, zomwe zimapereka mitundu yonse ya ma transformer otsimikizika a UL. Chaka chilichonse, timatumiza ma transformer ambiriwa ku United States ndi Canada. Popeza tili ndi luso la IEEE/ANSI, CSA, DOE, NEMA, ndi miyezo ina, gulu lathu limaonetsetsa kuti likutsatira zofunikira zosiyanasiyana zolamulira. Kuphatikiza pa chiphaso cha UL, tilinso ndi ziphaso za CSA, MF, CESI, ndi malipoti oyesera a SGS a chipani chachitatu. Popeza tili ndi chidziwitso chambiri pa ntchito, tikumvetsa kuti ntchito iliyonse ili ndi zofunikira zapadera. Ichi ndichifukwa chake timapereka ma transformer osinthika, kulola kusintha kwa magetsi, mphamvu, njira yolumikizira, ndi kapangidwe kapadera kuti kagwirizane bwino ndi zosowa zanu. Transformer yokhazikika pa 2500 kVA ikhoza kusinthidwa kuti igwirizane ndi zofunikira za polojekiti yanu. Lumikizanani ndi Daelim Transformer lero kuti mulandire pepala la magawo, zojambula, ndi mtengo wa transformer yokhazikika pa 2500 kVA.
    chitsimikizo01
    chitsimikizo02
    chitsimikizo03
    chitsimikizo04
    chitsimikizo05
    chitsimikizo06
    chitsimikizo07
    chitsimikizo08
    chitsimikizo09
    01020304050607

    Zofotokozera za Transformer ya 2500 kVA(2.5 MVA)

    Gawo Gawo lachitatu Std. ANSI/IEEE Std C57 & DOE 2016 Std
    Kuyesa mphamvu 2000kVA (2.5MVA) Konzani Chakudya cha kutsogolo/kuzungulira chopanda kanthu
    Kuyika Pad Mount Kuchuluka kwa nthawi 60Hz
    Mphamvu ya HV 13200/6720V Chosinthira cha pompo Malo 5
    Voliyumu ya LV 600/347V Mphamvu yamadzimadzi 1600L
    Galimoto iti? 95 kV Kulemera konse 7000kG
    Galimoto ya LV 30 kV Palibe kutayika kwa katundu 2500W
    Gulu la Vector MuIn0 Pa kutayika kwa katundu 15000W
    Njira yozizira KHALANI ODALIRA NDI CHIKONDI Kusakhazikika 5.75%
    Zopangira Zozungulira Aluminiyamu Mtundu wa Utoto Munsell wobiriwira
    Madzi Oteteza Kuteteza Mafuta a masamba ovunda Kuchuluka kwa kutentha @ 65℃ 2500 kVA
    Mawonekedwe apakati Gawo lachitatu la magawo asanu Mpweya Wokakamizidwa (Mafani) Palibe

    Zinthu Zosinthira za 2500 kVA
    Zinthu Zosinthira za 2500 kVA
    Transformer ya ZGSL-H-2500/13.2-0.6 ili ndi mphamvu ya 2500 kVA (2.5 MVA). Transformer ya 2500 kVA yokhala ndi ma pad ili ndi mphamvu ya 13.2/7.62 kV yokhala ndi Wye connection, high voltage H0 grounding, ndi secondary voltage ya 600Y/347V Wye yokhala ndi low voltage H0 grounding.

    Transforma ya ZGSL-H-2500/13.2-0.6 2500 kVA ndi yosinthasintha, ndipo ndi yoyenera kuyikidwa mkati ndi kunja. Transforma iyi ili ndi mafuta a masamba omwe amatha kuwonongeka ndipo imasunga kutentha kwa 65°C. Imabwera ndi ma fuse atatu a ELSP ndi ma fuse atatu a bay-o-net kuti atetezedwe, pamodzi ndi ma bushing atatu a high-voltage, ma elbow arresters atatu (HV), ndi ma bushing anayi a low-voltage, iliyonse ili ndi mabowo 6. Malo oyikapo ma terminal otsika-voltage amalimbikitsidwa ndi Padmount plate. Kuphatikiza apo, transforma ya 2500 kVA yokhala ndi pad ili ndi switch ya load-break yokhala ndi malo anayi ndi chosinthira cha ma tap chokhala ndi malo asanu kumbali ya high-voltage.

    ZGSL-H-2500/13.2-0.6
    ZGSL-H-2500/13.2-0.6 ndi transformer ya 2500 kVA yokhala ndi magawo atatu yokhala ndi mndandanda wa UL. Transformer ya 2500 kVA yokhala ndi ma pad imatsatira muyezo wa IEEE C57.12.34 ndipo ikutsatira malamulo a DOE. Imapangidwa ndi ma conductor a aluminiyamu ndipo imapangidwa ngati transformer yamtundu wa loop-feed ya machitidwe a dead-front. Njira yozizira yomwe imagwiritsidwa ntchito ndi KNAN.

    ZGS-Z-2500(3050)/44/0.6
    ZGS-Z-2500(3050)/44/0.6 ndi transformer yapadera ya 2500 kVA yomwe imayikidwa kutsogolo kwa pad yopangidwa kuti ikwaniritse zofunikira zapadera za makasitomala aku Canada ndi Daelim Transformer. Transformer iyi ya 2500 kVA yomwe imayikidwa pad ikugwirizana ndi miyezo ya CSA C227.4 ndi CAN/CSA 802.1. Ili ndi voltage yayikulu ya 44 kV mu Delta configuration komanso voltage yochepa ya 600GrdY/347V.

    Transformer ili ndi mafuta a RAPO omwe amatha kuwonongeka ngati madzi ake oteteza kutentha ndipo yapangidwa kuti ikweze kutentha kwa 55°C kapena 75°C. Chiyeso chake cha kVA ndi 2500 kVA (2.5 MVA) pa kutentha kwa 55°C ndi 3050 kVA pa kutentha kwa 75°C.

    ZGS-Z-2500(3050)/44/0.6
    Chomwe chimasiyanitsa transformer iyi ya 2500 kVA ndichakuti mphamvu yake yotsika imapangidwa kuti ituluke m'mbali. Kuphatikiza apo, ma gauge, chosinthira tap, nameplate, valavu yochepetsera kupanikizika, ndi valavu yodzaza pamwamba zonse zili kunja kwa kabati yakutsogolo. Ma gauge awa ali ndi zolumikizira ndipo amalumikizidwa mkati mwa bokosi lowongolera lakunja la NEMA 4. Choyezera kupanikizika kwa vacuum chili pamwamba pa kabati yakutsogolo. Bushing yamagetsi apamwamba ndi bushing yolumikizidwa ndi porcelain yokhala ndi mabowo anayi, ndipo mbali ya HV ili ndi zotchingira mphezi zitatu, chilichonse chomwe chimapereka chivundikiro choteteza zingwe za MV. Kuphatikiza apo, zotenthetsera zotsutsana ndi condensation zimayikidwa mu kabati yakutsogolo yamagetsi apamwamba kuti zigwire bwino ntchito.
    2

    Transformer ya MVA 3 PH 2.5
    ZGSL-Z-2500/44/4.16(2.4) ndi transformer yapadera ya 2.5 MVA yokhala ndi magawo atatu yokhala ndi radial pad. Voltage yake yayikulu ndi 44,000 Delta V, pomwe voltage yachiwiri ndi 4160Y/2400 V. Transformeryi imapangidwa ndi gulu lolumikizira la DYn1 high ndi low voltage, ndipo imagwirizana ndi muyezo wa CSA C227.4. Ili ndi mphamvu yogwira ntchito bwino ya 99.37%, mogwirizana ndi muyezo wa CAN/CSA-802.3. Kuletsa kwa transformeryi pa 85°C ndi 5.75%, ndipo imapereka milingo isanu ndi iwiri ya voltage yolamulira mbali ya voltage yayikulu. Ndi mphamvu yamafuta yoteteza ya 2000L komanso kulemera kwa 7500 kg, ndi chida chofunikira kwambiri.
    2

    Transformer ya MVA ya 2.5
    Chochititsa chidwi n'chakuti, ili ndi kapangidwe komwe zigawo zonse ziwiri zamphamvu komanso zochepa zimayikidwa mbali yoyikirapo, ndipo gawo lamphamvu kwambiri lili ndi chipinda cholowera mpweya chokhazikika bwino chomwe chimafikira pansi pake. Kuphatikizidwa kwa ma valve a zida ndi zowonjezera zomwe zili pamalo abwino pakhoma la thanki yamafuta yakunja kumathandizira kuti zinthu zizitha kufikika mosavuta ndikuwonetsetsa kuti zinthu zikhale zosavuta, zomwe zikuwonetsa kapangidwe ka transformer kokonzedwa bwino.
    Transformer Yokwera pa Pad ya 2550 kVA

    Transformer Yokwera pa Pad ya 2550 kVA
    ZGSL-H-2550/34.5/0.415 ikuyimira transformer yolimba yokhala ndi ma pad okhala ndi magawo atatu, yokhala ndi mphamvu yodabwitsa ya 2550 kVA. Imagwira bwino ntchito ndi mphamvu yamagetsi ya 34.5 kV pomwe imapereka mphamvu yotsika ya 415Grd/240V. Chodziwika bwino ndi chakuti, ma windings ake onse amagetsi amphamvu (HV) ndi otsika (LV) amapangidwa mwaluso kwambiri kuchokera ku aluminiyamu. Transformer iyi ili ndi mphamvu yamagetsi ya 99.4% ndipo imagwirizana kwambiri ndi muyezo wa IEEE Std C57.12.34. Kuphatikiza apo, kuphatikiza kwake switch yoletsa kunyamula katundu yokhala ndi malo anayi kumathandizira kwambiri magwiridwe antchito ndi chitetezo.
    Transformer ya 2550 kVA

    Transformer ya 2550 kVA
    Chosinthira cha 2550 kVA chimagwiritsa ntchito makina oziziritsira a ONAN/ONAF, motero, chimakhala ndi mafani ambiri. Pogwira ntchito mu njira yoziziritsira ya ONAN, chosinthiracho chimakhala ndi mphamvu ya 2550 kVA. Komabe, njira yoziziritsira ya ONAF imatha kuthana ndi mphamvu ya 3300 kVA. Chodziwika bwino n'chakuti, chosinthiracho chili ndi choyezera kutentha kwa mafuta chokhala ndi ma alarm contacts ndipo chimalumikizidwa ku kabati kakang'ono ka 304 kowongolera chitsulo chosapanga dzimbiri. Kapangidwe kameneka kamalola kuyang'anira patali momwe chosinthiracho chikugwirira ntchito.

    Mndandanda wa ZGSL-H-2550/34.5/0.415 uli ndi mayunitsi anayi onse, opangidwa mwapadera ndi kupangidwa kwa makasitomala aku America, ndipo ali pa mndandanda wa UL kuti akwaniritse miyezo yokhwima yachitetezo ndi khalidwe.

    ZGSL-H-2550/12.47/0.415
    Mndandanda wa ZGSL-H-2550/12.47/0.415 uli ndi gulu la ma transformer a 2550 kVA opangidwa ndi JZP Transformer kwa makasitomala aku America. Ma transformer awa ndi amtundu wokhazikika pa pad ndipo ali ndi mawonekedwe olumikizirana. Mafotokozedwe ofunikira a ma transformer awa ndi switch ya malo anayi yotsegula load-break, chosinthira cha malo asanu chotsegula pompo, ma gauge okhala ndi mawonekedwe osakhudza, ma fuse atatu a bay-o-net, ndi ma fuse awiri oletsa current.
    12

    Transformer ya 12.47 kV 2550 kVA
    Kumbali ya magetsi otsika, pali bracket pamzere kuti ipereke chithandizo ku terminal. Madzi oteteza omwe amagwiritsidwa ntchito ndi mafuta a mineral a ASTM II, okhala ndi mphamvu ya magaloni 440. Thankiyo idapangidwa kuti ipirire kuthamanga kwa thanki kwa 10 PSI ndi kuthamanga kwa thanki kwa 8 PSI. Mlingo wamadzimadzi umasungidwa pa mainchesi 10.0 kuchokera pamwamba pa dzenje lamanja pa 25℃, ndi kusintha kwa milingo ya mainchesi 0.4 pa 10℃. Thankiyo idapangidwa kuti ikwaniritse vacuum ya PSI 7 ndipo imayesedwa kuti ikhale ndi 2550 kVA ikagwiritsidwa ntchito pa 11,847 volts ndi chosinthira cha tap pamalo a 124,700-volt kuti pakhale voltage yachiwiri ya 415Y/240. Ma transformer awa alibe milingo ya PCB (yosakwana 2 ppm) panthawi yopanga, kuonetsetsa kuti chitetezo cha chilengedwe ndi kutsatira malamulo.
    13

    Transformer ya 13.2 kV 2550 kVA
    Transformer ya 2550 kVA ndi transformer yopangidwa mwapadera yomwe ili ndi mndandanda wa UL, zomwe zimatsimikizira kuti ikutsatira miyezo yolimba yachitetezo komanso yapamwamba. Gulu lolumikizira la transformer iyi ndi Dy1·Dd0, lomwe limapereka njira ziwiri zosiyana zolumikizira magetsi otsika:

    Pa kulumikizana kwa 4160V Wye, ma terminals akuphatikizapo X1B, X2B, X3B pamalumikizidwe a gawo, X1A, X2A, ndi X3A pamalumikizidwe osalowerera. Pa kulumikizana kwa 2400V Delta, ma terminals ndi awa: C1B kupita ku X2A, X2B kupita ku X3A, ndi X3B kupita ku X1A.
    24

    Transformer ya 24.94 kV 2550 kVA
    Ma transformer onse a 2550 kVA omwe ali mu mndandanda uwu apangidwa kuti akwaniritse muyezo wa IEEE C57.12.34, kutsimikizira khalidwe lapamwamba komanso magwiridwe antchito. Ali ndi kapangidwe ka pakhosi kokhazikika pambali pa kulumikizana kwa voltage yochepa, zomwe zimathandiza kuti pakhale kulumikizana kosasunthika ndi switchgear. Kuphatikiza apo, switch yoletsa kunyamula katundu ya ma transformer a 2550 kVA awa yapangidwa mwaluso mkati mwa chipinda chotsika cha cabin yakutsogolo, imapereka malo anayi kuti azitha kusinthasintha. Chosinthira cha tap chimapereka malo asanu, ndipo zida zosinthira kupanikizika zimayikidwa pa 24.94±2×2.5% kuti ziwongolere bwino. Kuletsa kwa ma transformer awa pa 85°C ndi 5.87%, kuonetsetsa kuti ntchito yawo ndi yokhazikika komanso yothandiza. Kuphatikiza apo, Ma Insulation Levels (BILs) awo okhala ndi voltage yayikulu komanso yochepa amayesedwa pa 125kV ndi 30kV, motsatana, kuti atsimikizire kuti insulation ikugwira ntchito bwino.

    Funsani Tsopano!

    Ngati mukufuna kudziwa zambiri zokhudza zinthu zathu kapena mitengo yake, chonde titumizireni imelo yanu ndipo tidzakulumikizani mkati mwa maola 24.

    Leave Your Message