Transformer Yokwera Magawo Atatu ya 2000kVA
Mafotokozedwe Akatundu
Ma transformer a JZP Transformer a 2000kVA, 34.5kV okhala ndi ma pad-mounted amayikidwa mu Battery Energy Storage System (BESS) ku Kern County, California, komwe amapereka mphamvu yodalirika yothandizira zida zosiyanasiyana mkati mwa malo osungiramo mphamvu. Ma transformer awa atamalizidwa mu Meyi 2024 ndikuperekedwa kwa makasitomala aku America, ndi ofunikira kuti awonetsetse kuti ntchito yawo siikusokonekera komanso kuti azitha kuyendetsa bwino malo osungira mphamvu.
01020304050607
| Kutentha kwa malo ozungulira | Osachepera -15.0°C, Kuchuluka kwa 41.0°C, kuchuluka kwapakati kwa maola 24 ndi 33.0°C |
| Kukwera | |
| Mikhalidwe ya zivomerezi: | Gulu la Zoopsa: II, Gulu la Malo D |
| SS = 1.28 g, S1 = 0.43 g, SMS = 1.54 g, SM1 = 1.09 g, SDS = 1.03 g, SD1 = 0.73 g |
| Kugwira ntchito mwadzina (gawo mpaka gawo) | 34.5kV |
| Kugwiritsa ntchito kwambiri (gawo mpaka gawo) | 38kV |
| Kapangidwe ka kuzunguliza | Delta |
| Kuyesa kwa Bushing | 600A |
| Kuteteza ku mphepo | 200kV BIL |
| Kuteteza ku zinyalala | 200kV BIL |
| Kuchuluka kwa Bushing | Zisanu ndi chimodzi (Loop Feed) |
| Kupirira kwafupikitsa | 30kA |
| Chotsani | Sinthani ya LBOR |
| Kuchuluka kwa switch yolekanitsidwa | Gawo Limodzi (1) la magawo atatu |
| Kugwira ntchito mwadzina (gawo mpaka gawo) | 480V |
| Kapangidwe ka kuzunguliza | Wye Wokhazikika |
| Kuphimba ndi kutchingira matabwa BIL | Galimoto ya 30KV |
| Kupirira kwafupikitsa | 65 kA* |
| LV bushing spade hole quaty | (8) PALIBE mabowo awiri |
| Chinthu chowonjezera mphamvu zamagetsi nthawi zonse | 110% |
| Kukana kwakhazikika | Ayi |
| Basi yapansi | Inde |
| Voliyumu yoperekera magetsi ya dera lowongolera | 277V AC |
| Kufotokozera kwa choswa dera | UL yalembedwa |
| Yoyenera kulowa mu utumiki | Inde |
| Muyeso (mkati) | Kutalika: 83.9*94.7*95.3 |
| Tanki ndi Zowonjezera | 4,630lbs |
| Mafuta ochulukirapo | 900Gal |
| Kulemera Konse | 21,600lbs |
Zinthu Zofunika & Mapindu
Kugawa Mphamvu Moyenera Posungira Mphamvu
Ma transformer a 2000kVA adapangidwa kuti atsike kuchoka pa Medium Voltage (MV) kupita ku Low Voltage (LV), zomwe zimapangitsa kuti akhale abwino kwambiri polumikizana ndi ma switchboard mumakina osungira mphamvu. Kapangidwe ka stepdown aka ndikofunikira kuti zitsimikizire kuti magetsi akugawidwa bwino komanso modalirika ku zida zothandizira, kuthandizira magwiridwe antchito onse a zomangamanga za BESS.
Kuziziritsa Kokhazikika Komanso Kotsika Mtengo
Mogwirizana ndi kudzipereka kwa JZP Transformer kuti zinthu ziyende bwino, ma transformer amagwiritsa ntchito mafuta osungunuka ngati madzi ozizira. Njira yabwino yotetezera chilengedwe iyi sikuti imangopereka mphamvu zabwino zotetezera kutentha komanso imathandizira kugwiritsa ntchito mphamvu moyenera.
Kulimba ndi Chitetezo Chomangidwa Mkati
Ma Enclosure a NEMA 3R: Ma transformer athu ali m'ma enclosure amagetsi a NEMA 3R omwe sagwa mvula, sagwa ayezi, komanso sagwa chipale chofewa, okhala ndi malo otulutsira madzi omangidwa mkati. Ma enclosure amenewa amapereka chitetezo champhamvu ku zinthu zakunja, kuteteza zida zamagetsi zamkati ndikuwonetsetsa kuti zimakhala zolimba kwa nthawi yayitali ngakhale m'malo ovuta.
Zinthu Zoletsa Kusokoneza ndi Chitetezo: Zopangidwa poganizira za chitetezo, ma transformer ali ndi njira zina zotsekera ndi kutsekera kuti apewe kulowa ndi kusokoneza kosaloledwa, kuchepetsa chiopsezo cha kuba ndikuwonetsetsa kuti ntchito ikuyenda bwino nthawi zonse.
Kapangidwe Kosavuta Kugwiritsa Ntchito Kuti Pakhale Chitetezo ndi Kugwira Ntchito Mwachangu
Mbali ya transformer yokhala ndi mphamvu zochepa ili ndi kapangidwe kapadera kokhazikika m'mbali komwe kali ndi pakhosi kuti kalumikizidwe mosavuta ku switchboard. Ma gauge oyikidwa kunja, ma valve oyesera, ndi makina otulutsira madzi amaikidwa mu kabati yotsekedwa yokhala ndi loko ya bolt ya mfundo zisanu. Kapangidwe kapadera aka kamalola ogwiritsa ntchito kuyang'ana mosamala kuchuluka kwa mafuta, kuyesa ma gauge, ndikuchita ntchito zokonza popanda kudziika pa ma bushings amphamvu (HV) kapena otsika mphamvu (LV), zomwe zimapangitsa kuti chitetezo ndi magwiridwe antchito azigwira ntchito bwino.

Ma geji akunja opangidwa ndi transformer
Kuwunika Kwambiri & Zidziwitso Zakutali
Kuti zitsimikizire kuti zikugwira ntchito bwino nthawi zonse, transformer ili ndi zizindikiro za mulingo wa mafuta ndi kutentha zomwe zimakhala ndi malo awiri olumikizirana kuti ziwunikire patali. Zizindikirozi zimapereka deta yeniyeni kwa ogwiritsa ntchito, kutumiza zizindikiro za alamu pamene mulingo wa mafuta uli wokwera kwambiri kapena wotsika kwambiri. Kuphatikiza apo, ngati kutentha kwa madzi ozizira kupitirira 85°C, makinawo adzayambitsa alamu. Ngati kutentha kukwera pamwamba pa 105°C, transformer idzachoka yokha pa gridi kuti ipewe kutentha kwambiri komanso kuwonongeka komwe kungachitike, ndikuwonetsetsa kuti makinawo ndi otetezeka komanso odalirika.

Ubwino ndi Kutsatira Malamulo
Ma JZP Transformers amapangidwa motsatira kwambiri miyezo yotsogola yamakampani, kuphatikizapo UL, ANSI, IEEE, ndi NEMA, kuonetsetsa kuti magwiridwe antchito, kudalirika, komanso chitetezo ndi apamwamba kwambiri. Kudzipereka kwathu ku khalidwe ndi kupanga zinthu zatsopano kumatsimikizira kuti transformer iliyonse imapangidwa motsatira zofunikira kwambiri, kupereka ntchito yodalirika nthawi yonse ya zida.

Funsani Tsopano!
Ngati mukufuna kudziwa zambiri zokhudza zinthu zathu kapena mitengo yake, chonde titumizireni imelo yanu ndipo tidzakulumikizani mkati mwa maola 24.