Leave Your Message

69kV 4200kVA 5250kVA Mphamvu Yosinthira Magawo Atatu

Ma Voltage Ratings Oyambirira: 110kv, 115kv, 121kv kapena ena
Ma Voltage Yachiwiri: 11/10.5/6.6/6.3kV kapena zina
MALO OGWIRITSA NTCHITO YA HV: ± 8×1.25% kapena ena
Mtundu Wolumikizira: YNd11 kapena ena
Mtundu: chosinthira mafuta choviikidwa mu mafuta kapena chosinthira cha substation

    Mafotokozedwe Akatundu

    69kV 4200kVA 5250kVA Mphamvu Yosinthira Magawo Atatu
    Ma transformer amphamvu a 110 kV 115 kV malinga ndi muyezo
    1. GB 6451 Mafotokozedwe ndi zofunikira zaukadaulo za ma transformer amagetsi odzazidwa ndi mafuta;
    2. Ma Transformer a IEC 60076 a Mphamvu;
    3. AS NZS 60076 Power Transformers;
    4. CSAC88-16 Zosinthira Mphamvu;
    5. ANSI/IEEE C57.12.00 Muyezo wa IEEE wa Zofunikira Zonse za Kugawa, Mphamvu, ndi Kulamulira Ma Transformers Omwe Amathiridwa Madzi;
    6. GOST R 52719 Power Transformers - Zambiri Zofunikira;
    7. EN60076 Transformer Yamagetsi;
    8. Ntchito Zapafupi Pambuyo Pogulitsa Ku North America South America ndi madera ena zimayankha zosowa zanu mkati mwa maola 24.
    Chosinthira cha 115kV
    SF11-20000/115 ndi transformer yamphamvu ya 115 kV 20 MVA, yoperekedwa ndi JZP Transformer. Transformer iyi imatsatira miyezo yokhwima yopangira ya ANSI C57 Std. Ili ndi mphamvu yamagetsi ya 115 kV komanso mphamvu yamagetsi ya 13.8 kV.
    JZP Transformer ili ndi luso lambiri komanso mbiri yabwino pantchito zosinthira zamagetsi zamagetsi pamsika waku America. Magulu awo aukadaulo ndi ogulitsa akuwonetsa kumvetsetsa kwakukulu kwa malamulo am'deralo komanso kutsatira miyezo ya ANSI, IEEE, ndi CSA. Ma transformer a Daelim Transformer a HV apeza ntchito zopambana m'mafakitale osiyanasiyana ku United States, Canada, Mexico, Australia, Ecuador, ndi mayiko ena.
    Chosinthira cha 115kV
    Zinthu Zofunika pa Transformer ya 115 kV 20 MVA
    Voltage: Transformer iyi imagwira ntchito pa 115 kV ndipo ili ndi mphamvu zambiri za 20 MVA.
    Chosungira Mafuta: Chokhala ndi chosungira mafuta kuti chigwire bwino ntchito komanso kuti chikhale ndi moyo wautali.
    Chizindikiro cha Vekitala: Transformer imatsatira chizindikiro cha Dyn1 vekitala.
    Njira Zoziziritsira: Amagwiritsa ntchito njira yoziziritsira yosinthasintha, kuphatikizapo njira za ONAN, ONAF1, ndi ONAF2. Mphamvu zomwe zimagwiritsidwa ntchito zimasiyana malinga ndi njira izi: 12 MVA ya ONAN, 16 MVA ya ONAF1, ndi 20 MVA yolimba ya ONAF2.
    Mlingo Woteteza: Mlingo woteteza mphamvu yamagetsi yamphamvu umakhala pa 550 kV, pomwe mlingo woteteza mphamvu yamagetsi yamphamvu ndi 110 kV.
    Kuyeza Kutentha: Transformer iyi idapangidwa kuti igwire kutentha kozungulira kwa 65℃ komanso kutentha kwa mafuta kwa 55℃.
    Chosinthira Mapaipi: Mbali ya HV ili ndi chosinthira mapaipi cha malo 5 chosinthasintha, chomwe chimalola kuti magetsi azikhala ndi mphamvu zisanu mkati mwa ±2×2.5%.
    Ma Bushings: Ma Bushings amphamvu komanso otsika amaikidwa pamwamba mosavuta.
    Zoletsa Kuthamanga kwa Maginito: Kuti pakhale chitetezo chokwanira komanso chitetezo, mbali yamagetsi okwera imakhala ndi zoletsa zitatu zoletsa kuthamanga kwa maginito.
    Zinthu Zofunika pa Transformer ya 115 kV 20 MVA
    Chosinthira cha 110kV 115kV
    Ma transformer amphamvu a 115kV/110kV apangidwa ndi kukonzedwa bwino mwa kuyamwa ndi kugwiritsa ntchito ukadaulo wapamwamba mdziko muno ndi kunja kuti akonze bwino pakati pa transformer, coil, body, leads, fuel tank, ndi zina, zomwe zimakhala ndi kutulutsa pang'ono pang'ono, kutayika kochepa, phokoso lochepa, kupepuka, komanso kudalirika kwambiri. Kugwira ntchito kwake bwino kwatamandidwa kwambiri ndi ogwiritsa ntchito ndi akatswiri oyenerera. Chogulitsachi chili ndi makhalidwe okhazikika, osawononga ndalama, komanso oteteza chilengedwe, ndipo ndi choyenera mafakitale amagetsi, malo osungiramo zinthu, mabizinesi akuluakulu amakampani ndi mineralization, ndi zina zotero.
    Chosinthira cha 110kV 115kV
    Kuyesa ndi Kuyenerera
    Transformer ya 115 kV 20 MVA imayesedwa motsatizana kuti iwonetsetse kuti ikukwaniritsa miyezo yokhwima yomwe idakhazikitsidwa ndi ANSI C57. Mayeso awa akuphatikizapo:
    Kuyeza kwa Kuteteza Kutentha
    Kuyeza kwa Voltage Ratio ndi Vector Group
    Kuyeza kwa Ma Parameter Ozungulira
    Mayeso Olimbana ndi Mphamvu Yowonjezera Mafunde a Voltage
    Kuyeza kwa Bushing Capacitance ndi Dielectric Dissipation Factor
    Mayeso Opirira Mphamvu ya Voltage Yowunikira
    Kuyesedwa Kopitilira Mphamvu Yowonjezera Mphamvu ndi Kutulutsa Pang'ono
    Kuyeza kwa Impedance Voltage ndi Kutayika kwa Katundu
    Kuyeza kwa Zero-Sequence Impedance Test of Phokoso
    Mayeso a Chisindikizo cha Kupanikizika Mayeso a Kukwera kwa Kutentha
    Kuyeza kwa Mzere Woyankha wa Mafupipafupi a Mafupipafupi a Mapiri
    Mayeso a Transformer apano Mayeso a Polarity Dimension Test
    Mayeso ambiriwa akutsimikizira kuti chosinthira cha 115 kV chikutsatira miyezo ya ANSI C57 ndipo chili ndi ziyeneretso zonse, zomwe zikutsimikizira kudalirika kwake ndi magwiridwe antchito ake.
    Kuyesa ndi Kuyenerera
    Zofotokozera za Transformer ya Mphamvu ya 110kV ndi 115kV
    110kv Chosinthira mphamvu cha duplex cha magawo atatu chosinthira katundu
    Mlingo Volti Yophatikizidwa Palibe Kutayika kwa Katundu Kutaya Katundu Palibe Katundu wamakono Impendance yafupikitsa
    (kVA) HW LV
    6300 kVA 110kV ±8 6.3kv 10 36 0.8 10.5
    8000 kVA ×1.25% 6.6 kW 12 45 0.8
    10000 kVA   10.5kv 14.2 53 0.74
    12500 kVA 115kV ±8 11kv 16.8 63 0.74
    16000 kVA ×1.25%   20.2 77 0.69
    20000 kVA     24 93 0.69
    25000 kVA     28.4 110 0.64
    31500 kVA     33.8 133 0.64
    40000 kVA     40.4 156 0.58
    50000 kVA     47.8 194 0.58
    63000 kVA     56.8 234 0.52
    110kv Chosinthira mphamvu cha magawo atatu chozungulira chamagetsi chosinthira katundu
    Mlingo Volti Yophatikizidwa Palibe Kutayika kwa Katundu Kutaya Katundu Palibe Katundu wamakono
    (kVA) HV(kV) MV(kV) LV(kV)
    6300 kVA 110kv±8 35kv 6.3kv 12 47 0.95
    8000 kVA ×1.25% 37kv 6.6 kW 14.4 56 0.95
    10 MVA   38.5kv 10.5kv 17.1 66 0.89
    12.5 MVA 115kv±8   11kv 20.2 78 0.89
    16MVA ×1.25%     24.2 95 0.84
    20MVA       28.6 112 0.84
    25MVA       33.8 133 0.78
    31.5MVA       40.2 157 0.78
    40MVA       48.2 189 0.73
    50MVA       56.9 225 0.73
    63MVA       67.7 270 0.67

    Funsani Tsopano!

    Ngati mukufuna kudziwa zambiri zokhudza zinthu zathu kapena mitengo yake, chonde titumizireni imelo yanu ndipo tidzakulumikizani mkati mwa maola 24.