Transformer Yokwera Pachidutswa Chimodzi—25 kVA

Ma Voltage Ratings Oyambirira: 19920V
Ma Voltage Yachiwiri: 120/240V
MALO OGWIRITSA NTCHITO YA HV: 18924-20916V
Mtundu Wolumikizira: Ii0
Mtundu: Zachizolowezi
ANALI: 150/30kV
Miyezo: IEEE C57.12.20, ANSI C57.12
Ntchito: Kugawa

    Mafotokozedwe Akatundu

    JZP imachita bwino kwambiri popanga ma transformer a ANSI/IEEE/UL, kusonyeza ukatswiri komanso luso lalikulu m'misika ya Kumpoto ndi Kumwera kwa America. Amapereka ma transformer a 25 kVA okhala ndi gawo limodzi, omwe amatha kupangidwa, kupangidwa, ndikusinthidwa kuti akwaniritse miyezo yosiyanasiyana yapadziko lonse lapansi. Kudzipereka kwa JZP pakuchita bwino kwambiri kumawapangitsa kukhala bwenzi lodalirika pazofunikira zonse za transformer ku America ndi kwina.
    Transformer Yokwera Pachidutswa Chimodzi—25 kVA0
    25kVA 19.92kV Chosinthira Chimodzi
    DL-25/19.92/0.24(0.12), ndi transformer yopangidwa mwapadera yokhala ndi gawo limodzi lokhala ndi ndodo.
    Transformer ya 25 kVA yokhala ndi gawo limodzi imagwiritsa ntchito zinthu zozungulira za aluminiyamu zapamwamba kwambiri pazigawo zake zonse ziwiri zokhala ndi mphamvu yamagetsi yayitali komanso yotsika, kuonetsetsa kuti ikugwira ntchito bwino komanso yodalirika. Ndi mphamvu ya impedance ya 2%, ili ndi gulu la Vector la Ii0 ndi polarity yomwe ndi yocheperako, zomwe zimapangitsa kuti ikhale yogwira ntchito bwino.
    Volti yapamwamba ya transformer yokhala ndi magawidwe asanu osiyana a voltage, imapereka kusinthasintha kwakukulu, pomwe voti yolamulira ya 19.92kV±2×2.5% imatsimikizira kukhazikika kokhazikika ngakhale panthawi yosinthasintha.
    25kVA 19
    25kVA 7.2(12.47)kV/4.8(8.32)kV Chosinthira Chimodzi
    Transformer ya 25 kVA yokhala ndi pole imodzi yokhala ndi ma voltage awiri. Izi zimathandiza kusankha mosavuta magetsi okwera kuchokera pa 7.2kV kapena 4.8 kV, zomwe zimagwirizana bwino ndi zofunikira zosiyanasiyana za zida zonyamula katundu, zomwe zimapereka kusinthasintha kosayerekezeka.
    Transformeryi ili ndi makina oziziritsira a ONAN ogwira ntchito bwino, ophatikizidwa ndi mafuta a mchere 45# opanda PCB, kuonetsetsa kuti chitetezo ndi udindo pa chilengedwe.
    Pogwiritsa ntchito gulu lodalirika la vector la Ii6 komanso polarity yowonjezera, transformer iyi ndi yapamwamba kwambiri pakugwira ntchito komanso kudalirika. Zowonjezera zazikulu zimaphatikizapo bushing imodzi yamagetsi amphamvu, bushing zitatu zamagetsi otsika, switch imodzi yamagetsi awiri, relief pressure imodzi, terminal imodzi ya H2, zingwe ziwiri zamkuwa, malo atatu osungiramo thanki, ma support lugs awiri, ma lift lugs awiri, ndi ma cover clamps asanu ndi limodzi, zomwe zimatsimikizira kapangidwe kake kapamwamba komanso kothandiza.
    25kVA 7
    25kVA 17.32kV Chosinthira Chimodzi
    Transformer iyi ili ndi voteji yoyamba ya 17.32 kV ndi voteji yachiwiri ya 230V, yopangidwa mosamala kuti ikwaniritse zofunikira za kasitomala.
    Ndi mkuwa wozungulira pakati pake, transformer iyi imatsimikizira magwiridwe antchito abwino komanso kudalirika. Imagwira ntchito pafupipafupi ya 50 Hz ndipo ili ndi gulu la Vector la Ii0 lokhala ndi polarity yowonjezera, imatsimikizira kuphatikizana bwino m'makina osiyanasiyana amagetsi.
    Transformer yokhala ndi malamulo okhwima a 17.32kV±2×2.5%, zomwe zimathandiza kutulutsa mphamvu yamagetsi yolondola komanso yokhazikika ngakhale pakakhala zovuta zosiyanasiyana.
    25kVA 17