Chosinthira Mphamvu cha 35MVA 115kV cha magawo atatu
Mafotokozedwe Akatundu
Chosinthira Mphamvu cha 35MVA 115kV 3 Phase Power, ndi chipangizo chamagetsi chamakono chomwe chapangidwa kuti chigwire ntchito zofunika kwambiri pamapulojekiti a mphamvu zongowonjezwdwa. Chapangidwa kuti chikwaniritse miyezo yapamwamba kwambiri ya magwiridwe antchito, kudalirika, komanso kugwiritsa ntchito bwino mphamvu, kuonetsetsa kuti chikugwira ntchito bwino m'makina amagetsi achikhalidwe komanso ongowonjezwdwa.
Zinthu Zofunika & Magwiridwe Abwino
Kutsatira malamulo a IEEE C57.12.00: Transformer ya 35MVA 115kV imatsatira miyezo yapadziko lonse lapansi, kuonetsetsa kuti ili ndi khalidwe labwino komanso magwiridwe antchito abwino.
Kutayika Kochepa ndi Kuchita Bwino Kwambiri: Chopangidwa ndi chitsulo chosinthira mphamvu chomwe chimataya mphamvu zochepa komanso mkuwa, chimachepetsa kwambiri kugwiritsa ntchito mphamvu, zomwe zimathandiza kuti chikhale chokhazikika komanso chotsika mtengo.
Kuchepetsa Kutuluka kwa Mpweya ndi Phokoso: Yopangidwa kuti igwiritsidwe ntchito potulutsa mpweya pang'ono (PD) komanso kutulutsa phokoso, imatsimikizira kuti ikugwira ntchito bwino komanso kuti ikhale yokhazikika kwa nthawi yayitali.
Kukana kwa Dera Lalifupi: Transformeryi idapangidwa kuti izitha kupirira mafunde amphamvu, zomwe zimapangitsa kuti chitetezo chonse komanso kulimba kwa dongosololi zikhale bwino.
Kapangidwe Kopanda Kutayikira: Ndi kapangidwe kolimba, transformer iyi yapangidwa kuti isawononge mafuta, zomwe zimapangitsa kuti chitetezo cha chilengedwe chikhale cholimba komanso kuti makina azigwira ntchito bwino.

Chosinthira Mphamvu cha 35MVA 115kV
Zipangizo Zapamwamba ndi Zomangamanga
1. Zipangizo za Pakati ndi Ma Coil: Pakati pa transformeryi ndi yopangidwa ndi chitsulo cha silicon chapamwamba kwambiri, chomwe chimalowa mosavuta, chokhala ndi njira yapamwamba yolumikizirana pa 45° kuti maginito azitha kuyenda bwino. Pamwamba pake pali chotchinga chapadera choletsa kuwononga, chomwe chimachepetsa kutayika kwa katundu komanso kuchepetsa phokoso.
2. Phokoso Lochepa ndi Kulimba Kwambiri: Cholumikizira cha coil ndi core chimaphatikizapo mapangidwe apadera monga core bracing ndi kugwiritsa ntchito mawaya a conductor osinthidwa, kuonetsetsa kuti phokoso limakhala lochepa komanso lokhazikika kwa nthawi yayitali.
Chosinthira Tap Chomwe Chili Pakatundu (OLTC)
1. Transformer ya 35MVA ili ndi On-Load Tap Changer (OLTC) kumbali yamagetsi amphamvu, zomwe zimathandiza kuti magetsi aziyenda bwino pa 115kV ± 8 × 0.625%.
2. OLTC ili ndi chosungira, chizindikiro cha kuchuluka kwa mafuta, Buchholz relay, ndi chopumira chodzibwezeretsa, zonse zomwe zimathandiza kuti transformer igwire ntchito bwino komanso mokhazikika.
Chitetezo ndi Chitetezo Mbali
1. Chitetezo cha Gasi ndi Kusiyanitsa: Transformer ili ndi zotetezera mpweya ndi zotetezera zosiyana kuti zitsimikizire kuti zikugwira ntchito bwino komanso kuzindikira zolakwika koyambirira.
2. Kuyang'anira Kutumiza Zinthu: Chipangizochi chili ndi ma relay amkati ndi akunja omwe amayambitsa ma alarm ndikuyamba kugwedezeka kokha ngati papezeka kusintha kulikonse kwa mpweya kapena mafuta.
3. Kuyang'anira Mlingo wa Mafuta: Zizindikiro za kuchuluka kwa mafuta zimayang'anira momwe thanki ya mafuta ilili, ndipo ma alarm amayambitsidwa ngati kuchuluka kwa mafuta kuli kunja kwa mlingo womwe watchulidwa, zomwe zimatsimikizira kuti mafuta akusamalidwa bwino.
Valavu Yothandizira Kupanikizika
Ngati mpweya wamkati ukuwonjezeka mofulumira chifukwa cha vuto, transformer imakhala ndi valavu yochepetsera kupanikizika. Dongosololi limatulutsa mpweya wochulukirapo, kuletsa kupanikizika kwambiri ndikulola chipinda chowongolera kuchitapo kanthu mwachangu poyambitsa kugwedezeka kwadzidzidzi.
Kuwunika Kutentha
Zizindikiro za Kutentha kwa Mafuta ndi Kuzungulira: Transformer ili ndi masensa owunikira kutentha kwa mafuta ndi kuzungulira. Ngati kutentha kupitirira 95°C, chizindikiro cha alamu chimatumizidwa ku chipinda chowunikira chakutali. Ngati kutentha kupitirira 105°C, transformer idzagwa yokha kuti isatenthe kwambiri komanso kuti isawonongeke.
Dongosolo Loziziritsa
Transformer ili ndi njira yoziziritsira ya magawo awiri:
Gawo 1: Fani yoyamba yoziziritsira imayamba kugwira ntchito kutentha kozungulira kukapitirira 75°C.
Gawo lachiwiri: Fani yachiwiri imayamba kutentha kukafika madigiri 80 Celsius.
Kutentha kukatsika pansi pa 75°C, mafani amadzima okha, kuonetsetsa kuti kuziziritsa bwino komanso kuchepetsa kugwiritsa ntchito mphamvu.
Chopumira Chodzibwezeretsa
Thupi lalikulu la transformer ndi chosungira madzi chopopera ali ndi chopumira chodzibwezeretsa (Qualitrol brand). Chopumiracho chimagwiritsa ntchito desiccant yomangidwa mkati (silika gel) yomwe imayamwa chinyezi ndikuchikonzanso kudzera mu kutentha, kuteteza chinyezi ndi mpweya kulowa mu transformer. Izi zimatsimikizira kuti chotenthetseracho chimakhala chouma, zomwe zimathandiza kuti transformeryo ikhale yolimba kwa nthawi yayitali.
Mapulogalamu
1. Mapulojekiti a Mphamvu Zongowonjezedwanso (Dzuwa, Mphepo, ndi zina zotero)
2. Kugawa Mphamvu Zamakampani
3. Kukhazikika kwa Gridi
4. Machitidwe Amphamvu Odalirika Kwambiri

Mapeto
Chosinthira Mphamvu Chachitatu cha 35MVA 115kV ndi njira yatsopano komanso yogwira ntchito bwino kwambiri pamakina amakono ogawa mphamvu, makamaka m'magawo amagetsi ongowonjezwdwa. Ndi zipangizo zapamwamba, mawonekedwe apamwamba achitetezo, komanso kapangidwe kosunga mphamvu, imapereka magwiridwe antchito apamwamba, kudalirika, komanso moyo wautali wautumiki. Chogulitsachi chikuwonetsa kudzipereka kwa JZP Transformer popereka mayankho atsopano komanso abwino kuti akwaniritse zofunikira za tsogolo lamphamvu lokhazikika.
Kodi Mwakonzeka Kulimbikitsa Tsogolo la Mphamvu?
Lumikizanani nafe lero kuti mudziwe zambiri za momwe Transformer ya Mphamvu ya 35MVA 115kV ya Magawo Atatu ingathandizire mapulojekiti anu amagetsi ongowonjezedwanso ndikuwonetsetsa kuti magetsi agawika bwino komanso modalirika.

Funsani Tsopano!
Ngati mukufuna kudziwa zambiri zokhudza zinthu zathu kapena mitengo yake, chonde titumizireni imelo yanu ndipo tidzakulumikizani mkati mwa maola 24.