+86 18068001229 01
Ma Transformer Okhala ndi Magawo Atatu a 500kVA Ogwira Ntchito Mwapamwamba Kwambiri Ogwiritsidwa Ntchito Pamakampani
Makhalidwe a Kapangidwe
Kore
Zitsulo zachitsulo za silikoni zozungulira mozizira: Zimalowa madzi ambiri ndi insulation yopangidwa ndi laminated kuti muchepetse kutayika kwa eddy current.
Kapangidwe ka miyendo isanu ya magawo atatu: Kumachepetsa zero-sequence impedance ndikuletsa ma harmonics.
Ma windings
Kupindika kwa Voltage Yaikulu: Chophimba cha foil cha mkuwa chokhala ndi Nomex paper insulation kuti chikhale cholimba ndi voltage yaikulu.
Kutseka kwa Voltage Yotsika: Kapangidwe ka cylindrical ka zigawo zambiri kuti kakhale kolimba kwambiri.
Tanki ndi Kuziziritsa
Zipsepse za radiator zopangidwa ndi corrugated: Kuziziritsa kwachilengedwe kwa convection popanda mafani akunja.
Kapangidwe kotsekedwa bwino: Kumaletsa kuipitsidwa kwa mafuta ndi kuipitsidwa.
Dongosolo Loteteza Kutupa
Mafuta a mchere (okhazikika) kapena mafuta a FR3 ester (osawononga chilengedwe), omwe amapereka kutentha, kuziziritsa, komanso kutha kwa arc.
Mulingo wochepa wotulutsa madzi ≤50pC (IEC 60076 ikugwirizana ndi malamulo).




Mapulogalamu
Mapaki a Mafakitale
Imathandizira makina olemera, mizere yopangira (monga makina osindikizira, ma crane), ndipo imathandizira kudzaza zinthu kwakanthawi kochepa.
Malo Ogulitsira
Amagawa magetsi owunikira, makina a HVAC, ma elevator, ndi chitetezo m'masitolo akuluakulu, mahotela, ndi maofesi.
Mapulojekiti a Zomangamanga
Malo osungiramo sitima, malo oyeretsera madzi otayira, ndi makina opangira magetsi a pa eyapoti.
Kukonzanso Gridi Yakumidzi
Imalowa m'malo mwa ma transformer okalamba kuti iwonjezere kudalirika komanso kugwiritsa ntchito bwino mphamvu.
Ubwino Waukulu
Kudalirika Kwambiri
Imapambana mayeso a IEC 60076 opirira ma short-circuit, kuonetsetsa kuti zinthu zikuyenda bwino nthawi ya gridi.
Thanki yotsekedwa bwino imawonjezera nthawi ya moyo wa mafuta (yopanda kukonza mpaka zaka 10).
Kugwiritsa Ntchito Mphamvu Moyenera
Kutaya katundu pang'ono kumachepetsa ndalama zogwirira ntchito, mogwirizana ndi miyezo ya IEEE C57.12.
Kusintha kwa Zachilengedwe
Imagwira ntchito kutentha kwambiri (-40℃ mpaka +55℃) komanso m'malo okwera (≤3,000m).
Zosankha Zanzeru
Imathandizira kuphatikiza kwa IoT ndi masensa otenthetsera, zowunikira mulingo wamafuta, ndi ma alamu akutali.
Chitsimikizo chadongosolo
Chipinda chilichonse chimayesedwa mwamphamvu, kuphatikizapo:
Kukana kwa insulation ndi mayeso a mphamvu yamagetsi.
Kutayika kwa katundu ndi miyeso ya kutayika kopanda katundu.
Kutsimikizika kwa short-circuit kupirira.
Yavomerezedwa ndi ISO 9001, ISO 14001, ndi KEMA chifukwa chotsatira malamulo apadziko lonse lapansi.
Malangizo Osankha
Zofunikira pa Katundu
Katundu Wosalekeza: Sankhani ma transformer omwe ali ndi ≥125% ya katundu wofunikira kwambiri (monga, 500kVA pakugwiritsa ntchito 400kVA mosalekeza).
Kuchuluka Kwambiri Kwakanthawi Kochepa: Ntchito zamafakitale zingafunike mphamvu yokwana 150% kwa mphindi 30.
Mikhalidwe Yachilengedwe
Chinyezi/Kupopera Mchere: Madera a m'mphepete mwa nyanja amafunika zophimba zoteteza dzimbiri.
Zofunikira pa Malo: Onetsetsani kuti pali malo okwana ≥1.5m ozungulira transformer kuti ikonzedwe.
Kutsatira malamulo
Imakwaniritsa IEC 60076, IEEE C57.12, GB 1094 (China), ndi ATEX pa malo oopsa.
Kusankha Mafuta
Mafuta a Mchere: Otsika mtengo pa malo okhazikika.
Mafuta a Ester a FR3: Osapsa ndi moto komanso oteteza chilengedwe m'malo ovuta (monga malo osungira deta).
Kukhazikitsa ndi Kusamalira
Kukhazikitsa
Gwiritsani ntchito maziko olinganira okhala ndi kukana kwa nthaka ≤4Ω.
Ma interface a chingwe amathandiza zingwe za 185mm² (pansi kapena mbali).
Kusamalira Kwachizolowezi
Kotala lililonse: Yang'anani mulingo wa mafuta, mtundu, ndi kutuluka kwa madzi.
Chaka chilichonse: Yesani kukana kutentha (2,500V megohmmeter) ndikuchita kusanthula kwa mafuta a chromatography.
Kuthetsa Mavuto
Kutentha Kwambiri: Yang'anani kutsekeka kwa radiator kapena kuchuluka kwa zinthu zosazolowereka.
Kutulutsa pang'ono: Gwiritsani ntchito chromatography ya mafuta kuti mupeze zolakwika zamkati mwa insulation.



Chifukwa chiyani mutisankhe
JIEZOU POWER, katswiri wopanga, wopanga komanso wokhazikitsa njira zamagetsi padziko lonse lapansi, idakhazikitsidwa mu 1989, ndipo ili ndi malo okwana mita lalikulu 200,000.
JIEZOU POWER, makamaka imayang'anira mapulojekiti a gridi yamagetsi, 500KV EPC, malo opangira magetsi a 230KV, malo osinthira magetsi a 115KV, ndi zina zotero.
Fakitale ya JIEZOU POWER imatha kupanga chosinthira chogawa mafuta chamtundu wamafuta ndi chouma, chosinthira mphamvu cha 500KV 480MVA champhamvu, GIS, switchgear, substation, kutengera muyezo wa ANSI/IEEE/DOE2016/CSA/IEC60076.
JIEZOU POWER imapeza ISO9001, ISO14001, ISO45001, UL, CUL, CSA satifiketi, SGS, TUV, INTERTEK, TYPE TEST REPORT. Mpaka chaka cha 2023, makampani ndi mafakitale padziko lonse lapansi amagawidwa ku United States, Canada, Dubai, Dominican Republic, Philippines, mafakitale ndi makampani a nthambi zaku China ali mumzinda wa BengBu, mzinda wa FengYang, mzinda wa HaiAn, mzinda wa TaiZhou, mzinda wa SuZhou, mzinda wa ShenYang, mzinda wa FoShan.
Poganizira za mtsogolo, masomphenya a JIEZOU POWER ndikukhala wopereka mayankho odalirika kwambiri a machitidwe amagetsi, kuthetsa mavuto ofunikira kwambiri padziko lonse lapansi okhudza kayendetsedwe ka mphamvu, kufulumizitsa kusintha kwa dziko lapansi kukhala mphamvu zongowonjezwdwanso. Kuti aliyense akhale ndi moyo wopanda mpweya wambiri komanso wowala. Pachifukwa ichi, tidzachita zonse zomwe tingathe kuti tipeze mphamvu.



Funsani Tsopano!
Ngati mukufuna kudziwa zambiri zokhudza zinthu zathu kapena mitengo yake, chonde titumizireni imelo yanu ndipo tidzakulumikizani mkati mwa maola 24.








