+86 18068001229 01
Makina Olimba Omwe Amaviikidwa mu Mafuta Okhala ndi Magawo Atatu
Makhalidwe ndi Mapindu Aakulu
Kuziziritsa Bwino ndi Kukhalitsa
Choviikidwa mu mafuta abwino kwambiri oteteza kutentha, transformer imachotsa kutentha bwino (kuzizira kwa ONAN/ONAF), ndikusunga magwiridwe antchito abwino ngakhale ikalemera kwambiri. Mafutawa amagwiranso ntchito ngati chotetezera kutentha, kulimbitsa chitetezo chamagetsi ndikuchepetsa kuwonongeka.
paKudalirika Kwambiri & Kusamalira Kochepa
Kapangidwe kolimba kokhala ndi zozungulira zamkuwa komanso makina apamwamba otetezera mafuta a pepala amatsimikizira kuti sikhala ndi kutentha, chinyezi, komanso ma circuit afupiafupi. Zofunikira zochepa pakukonza zimapangitsa kuti ikhale yoyenera m'malo akutali kapena ovuta kufikako.
paKapangidwe Kakang'ono & Kofanana
Imapezeka mu ma voltage rating kuyambira 11kV mpaka 33kV ndipo imatha kufika pa 5 MVA, yokhala ndi ma configurations amodzi kapena atatu. Kukula kochepa kumapangitsa kuti kuyika kukhale kosavuta m'malo osungira magetsi m'mizinda, m'mapaki a mafakitale, kapena m'ma network akumidzi.
paKuwunika Mwanzeru (Mwasankha)
Masensa ogwiritsira ntchito IoT (ngati mukufuna) amapereka deta yeniyeni pa kutentha kwa mafuta, kuchuluka kwa katundu, ndi kuzindikira zolakwika, zomwe zimathandiza kukonza zinthu molosera komanso kuchepetsa nthawi yogwira ntchito.
paYosamalira Chilengedwe Komanso Yotsika Mtengo
Kugwiritsa ntchito phokoso lochepa (




Mapulogalamu
Maukonde a Nyumba: Kuchepetsa mphamvu yamagetsi yapakati (11kV/33kV) kufika pa 230/400V ya mabanja.
paZamalonda ndi Zamalonda: Mphamvu yokhazikika ya mafakitale opangira zinthu, malo osungira deta, ndi malo ogulitsira zinthu.
paKuphatikiza Kobwezerezedwanso: Kulumikiza mafamu a dzuwa/mphepo ku ma gridi opanda magetsi ambiri.
paKukhazikitsa Magetsi Kumidzi: Kapangidwe kolimba ka malo akutali kapena ovuta.
Mafotokozedwe Aukadaulo
Ma Voltage Range: 11kV mpaka 33kV (voltage yapakati).
paKutha: 500 kVA mpaka 5,000 kVA.
paKuchuluka kwa nthawi: 50Hz/60Hz.
paKuziziritsa: ONAN (Mafuta Achilengedwe Amlengalenga) kapena ONAF (Mafuta Achilengedwe Amlengalenga Okakamizidwa).
paKuchita bwino: ≥98% ikadzaza kwathunthu (yovomerezedwa ndi IEC 61378).
Chitsimikizo chadongosolo
Kuyesa kokhwima kumaonetsetsa kuti zikutsatira miyezo yapadziko lonse lapansi:
Mayeso a mphamvu ya dielectric kuti aone ngati insulation ndi yolimba.
Kuchepa kwa katundu ndi kuyeza kukwera kwa kutentha.
Kutsimikizika kwa short-circuit.
Yovomerezedwa ndi ISO 9001 (ubwino), ISO 14001 (chilengedwe), ndi KEMA chifukwa cha chitetezo ndi kudalirika.
Chifukwa Chiyani Sankhani Ife?
Ukatswiri wa Zaka 30+: Mapangidwe otsimikizika kuti agwiritsidwe ntchito m'malo osiyanasiyana a nyengo ndi ntchito.
paNetiweki Yothandizira Padziko Lonse: Magulu a ntchito zapakhomo komanso thandizo laukadaulo la maola 24 pa tsiku, masiku 7 pa sabata.
paMitengo Yopikisana: Mayankho osinthika ogwirizana ndi bajeti ndi zosowa za magwiridwe antchito.
Mayankho Amakonda
Mapangidwe Apadera: Kwa kutentha kwambiri, malo owononga, kapena madera omwe amakhudzidwa ndi zivomerezi.
paKukweza Kugwiritsa Ntchito Mphamvu Moyenera: Zida zokonzanso zinthu zakale.



Ubwino wa malonda
1. Zipangizo Zapakati ndi Kapangidwe ka Kuzungulira
Zipangizo Zazikulu
Mitundu ya Aloyi ya Amorphous:
Kutayika kwa chitsulo kochepa kwambiri (70–80% yotsika kuposa chitsulo cha silicon chachikhalidwe), kuchepetsa kuwononga mphamvu ndi ndalama zogwirira ntchito.
Kuchuluka kwa mpweya wolowera komanso kutsika kwa maginito pafupi ndi zero kumachepetsa phokoso ndi kugwedezeka, komwe ndi koyenera m'malo okhala ndi mafakitale.
Chitsulo cha Silicon Chozungulira Chozizira (CRGO):
Ma lamination odulidwa ndi laser kapena opindika pang'onopang'ono amachepetsa kutayika kwa mphamvu ya eddy, zomwe zimapangitsa kuti magwiridwe antchito azitha kufika pa 98.5%.
Kuwongolera bwino kwa tirigu kumawonjezera kuchuluka kwa maginito a flux kuti agwiritsidwe ntchito pamagetsi amphamvu (monga, 11kV–33kV).
Kapangidwe ka Winding
Mafelemu Oziziritsa Oyenda ndi Mafuta:
Ma winding a mkuwa kapena aluminiyamu amachepetsa kutuluka kwa madzi ndi mphamvu ya short-circuit. Kuyenda kwa mafuta kudzera m'mitsempha yozungulira kumawonjezera kutayika kwa kutentha.
Magawo a conductor olumikizana amachepetsa kupsinjika kwa magetsi pakati pa ma turn ndikuwongolera kulimba kwa ma short-circuit.
Ma Winding a Litz Wire Okhala ndi Magawo:
Waya wa Litz wa multi-strand umachepetsa zotsatira za khungu ndi kuyandikira kwa chipangizocho, kuchepetsa kukana kwa AC ndi kutayika kwa zinthu zomwe zimagwiritsidwa ntchito pafupipafupi.
Kapangidwe ka Core ka Ziwalo Zitatu Kakang'ono:
Kapangidwe ka maginito kamalinganiza mphamvu ya maginito, kuchepetsa kutayika kwa zero-sequence ndikuwonjezera kufanana kwa kutentha.
2. Makina Otetezera Kutentha
Chotetezera Mafuta ndi Pepala:
Pepala la cellulose labwino kwambiri lodzazidwa ndi mafuta oteteza (monga mafuta a naphthenic kapena paraffinic mineral) limapereka mphamvu ya dielectric mpaka 300 kV BIL.
Zimaphatikiza kukhazikika kwa kutentha (kupirira kutentha mpaka 140°C) ndi kukana moto.
Chophimba cha Epoxy Resin (Chosakanikirana ndi Mtundu Wouma):
Utomoni wa epoxy wosatulutsa madzi pang'ono womwe umathandiza kuti ukhale ndi coil encapsulation, womwe umathandiza kuti chinyezi chisawonongeke komanso kuti zinthu zisawonongeke.
Kuteteza Kowonjezereka kwa Nano:
Ma epoxy odzaza ndi silica amawonjezera nthawi yotulutsa madzi pang'ono ndi 30-50%, zomwe ndi zabwino kwambiri m'malo a m'mphepete mwa nyanja kapena m'mafakitale.
3. Kusamalira Kutentha
Kuziziritsa Mpweya kwa Mafuta ndi Zachilengedwe (ONAN):
Kuziziritsa kosalekeza kudzera mu ma radiator ndi convection yamafuta achilengedwe, yoyenera kugwiritsidwa ntchito mosalekeza pa katundu wovomerezeka.
Kuziziritsa Mpweya Mokakamizidwa (OFAF):
Mafani olamulidwa ndi kutentha amathandizira kutayikira kwa kutentha, zomwe zimapangitsa kuti mphamvu yodzaza ndi 120% ikhale yochepa.
Kuziziritsa Kothandizidwa ndi Pampu ya Mafuta (OFWF):
Mapampu oyendera mafuta ndi mafani oponderezedwa mpweya amakonza kusamutsa kutentha kwa malo osungiramo mafuta okhala ndi anthu ambiri m'mizinda.
Kuwunika kwa Kutentha kwa Smart:
Masensa otenthetsera omwe ali mkati ndi makina ogwiritsira ntchito IoT amayambitsa ma alarm, kutsika kwa katundu, kapena kuyatsa kuzizira kuti apewe kuwonongeka kwa insulation.
4. Kapangidwe ndi Chitetezo cha Kapangidwe
Thanki Yolimba ndi Malo Osungiramo
Matanki Osagonjetsedwa ndi Dzimbiri:
Zitsulo zomatira kapena aluminiyamu zoviikidwa m'madzi otentha zokhala ndi zokutira za polyurethane/ufa zimapewa kuwonongeka kwa UV, kupopera mchere, komanso kukhudzidwa ndi mankhwala.
Kutseka kwa Hermetic:
Matanki opangidwa ndi ma bolt kapena opangidwa ndi ma gasket a EPDM amaletsa mafuta kutuluka ndi kulowa kwa chinyezi, zomwe zimapangitsa kuti asagwiritsidwe ntchito kwa zaka zambiri.
Chithandizo Choletsa Kutupa:
Machitidwe oteteza ku cathodic ndi zokutira zosagwirizana ndi dzimbiri zimawonjezera moyo m'malo okhala ndi asidi kapena chinyezi.
Zinthu Zachitetezo
Ma Valves Othandizira Kupanikizika:
Mpweya umatuluka wokha pakagwa vuto la mkati (monga ma short circuits), zomwe zimathandiza kuti thanki isasweke.
Njira Yosungira Mafuta:
Matanki a Conservator kapena ma conservator otsekedwa amachepetsa kukhudzana kwa mpweya, kuchepetsa kukhuthala kwa okosijeni ndi kupangika kwa matope.
Chitetezo cha Kutupa:
Zomangira zinki oxide zolumikizidwa (MOA) ndi ma surge capacitor zimaletsa kusintha kwa mphamvu yamagetsi komwe kumachitika chifukwa cha mphezi.
5. Ntchito Zapamwamba
Machitidwe Oyang'anira Mkhalidwe (CMS):
Masensa amatsata kutentha kwa mafuta, kusanthula kwa mpweya wosungunuka (DGA), kuchuluka kwa katundu, ndi kutulutsa pang'ono, zomwe zimathandiza kukonza bwino kudzera mu SCADA.
Zosintha Ma Tap Pa-Load (OLTC):
Kusintha kwa matepi koyendetsedwa ndi AI kumathandizira kuyendetsa bwino magetsi pogwiritsa ntchito mphamvu zomwe zimasinthasintha pa gridi, zomwe zimachepetsa kutayika kwa mphamvu ndi 5%.
Zatsopano Zosamalira Chilengedwe:
Mafuta oteteza kutentha omwe ali ndi bio-based (monga ester fluids) omwe amatha kuwonongeka kwambiri komanso kutentha pang'ono, mogwirizana ndi miyezo ya IEC 62721.
Ntchito Zofunika Kwambiri ndi Zochitika Zamtsogolo
Kugawa kwa Mafakitale ndi Mizinda:
Mafakitale amphamvu okhala ndi mphamvu zambiri (500kVA–5MVA), malo ochitira malonda, ndi mizinda yanzeru.
Kuphatikiza Mphamvu Zobwezerezedwanso:
Yabwino kwambiri pa malo osungira magetsi a mphepo/dzuwa komanso ma microgrid, omwe amathandizira kuyenda kwa magetsi mbali zonse ziwiri.
Zotsatira Zamtsogolo:
Ma Transformers a Solid-State (SSTs): Amalola kusintha kwa DC-DC ndi kusinthasintha kwa gridi yamagetsi kuti pakhale mphamvu zogawanika.
Kudziteteza Kodzichiritsa: Zipangizo za nanocomposite zimakonza zokha zolakwika zazing'ono za dielectric.
Chidule
Ma Transformer Omwe Amathiridwa Mafuta Okhala ndi Magawo Atatu Amachita bwino kwambiri pogwiritsa ntchito ma cores a amorphous omwe amatayika pang'ono, kasamalidwe ka kutentha kwapamwamba, komanso machitidwe otetezera okhala ndi zigawo zambiri. Kuphatikiza kwawo kogwira ntchito bwino, kukula, komanso kulimba mtima kumawapangitsa kukhala ofunikira kwambiri pama gridi amagetsi amakono, pomwe zatsopano monga mafuta opangidwa ndi bio ndi anzeru



Funsani Tsopano!
Ngati mukufuna kudziwa zambiri zokhudza zinthu zathu kapena mitengo yake, chonde titumizireni imelo yanu ndipo tidzakulumikizani mkati mwa maola 24.