+86 18068001229 Kodi pali kusiyana kotani pakati pa ma Transformers opangidwa ndi pole ndi ma Pad-mounted?
Mwachidule: Kusiyana Kofunika Kwambiri

Kufotokozera Mwatsatanetsatane
Ma Transformers Okwezedwa ndi Ndodo
Awa ndi matanki ozungulira omwe mumawaona atamangiriridwa ku mitengo yogwiritsidwa ntchito ndi matabwa, nthawi zambiri amatsagana ndi zodulira za fuse ndi zida zina.
- Kumanga ndi Kukhazikitsa:Amamangiriridwa mwachindunji ku mtengo pakati pa mizere yamagetsi yoyambira (yamphamvu kwambiri) ndi yachiwiri (yamphamvu yochepa). Mawaya amphamvu kwambiri amalowa kudzeramatabwapamwamba, ndipo mawaya otsika mphamvu amatuluka kudzera mu vuto la nyengo lomwe lili m'mbali, kupita ku gawo la ntchito lomwe limalumikizana ndi nyumba.
- Ntchito:Ndiwo muyezo wapamwamba Kugawa Mphamvu Mudzawapeza mu:
1. Madera akale
2. Madera akumidzi
3. M'misewu ikuluikulu
4. Kulikonse komwe mawaya amagetsi amayendetsedwa pamwamba pa nthaka.
- Ubwino:
Mtengo Wotsika:Ndi zotsika mtengo kuziyika ndi kuzisamalira chifukwa sizifuna kukumba ngalande zokonzera mizere.
Kukonza Kosavuta:Anthu ogwira ntchito pa mzere amatha kuwapeza mosavuta pogwiritsa ntchito magalimoto onyamula katundu.
Malo Osavuta Olakwika:Mavuto nthawi zambiri amaonekera kuchokera pansi.
- Zoyipa:
Kukumana ndi Zinthu:Zitha kuonongeka ndi mphepo yamkuntho, mphepo yamphamvu, mitengo yogwa, komanso kugundana ndi zipilala zamagalimoto.
Kukongola:Ambiri amaona kuti ndi chinthu chosaoneka bwino.
Chiwopsezo cha Chitetezo:Pamene ali pamwamba, ngozi kapena mphepo yamkuntho imatha kuwagwetsa, zomwe zingabweretse ngozi.
Ma Transformers Okhala ndi Pad
Izi ndi makabati obiriwira, achitsulo, otsekedwa okhala pa simenti pansi, nthawi zambiri m'bwalo lakumbuyo, pamalo oimika magalimoto, kapena m'mbali mwa nyumba yamalonda.
- Kumanga ndi Kukhazikitsa:Ndi zomangira zolemera, zachitsulo, zosaphwanyika zomwe zimapangidwa kuti ziteteze anthu. Zingwe zonse zamphamvu komanso zotsika mphamvu zimalowa ndi kutuluka pansi pa nthaka. Zimadzazidwa ndi mafuta kapena madzi oteteza komanso osayaka kwambiri.
Ntchito:Amagwiritsidwa ntchito ndimakina ogawa magetsi pansi pa nthaka.Mudzawapeza mu:
1. Nyumba zogona zamakono
2. Malo ozungulira mzinda
3. Mapaki amalonda
4. Zipatala ndi masukulu
5. Malo aliwonse omwe mizere imabisika chifukwa cha kukongola kapena kudalirika.
- Ubwino:
Kudalirika Kwambiri:Kutetezedwa ku mphepo, ayezi, ndi mitengo yogwa, zomwe zimapangitsa kuti nyengo isawonongeke kwambiri.
Kukongola:Zosaoneka bwino kwambiri kuposa mizere ndi zipilala zapamwamba, zomwe zimapangitsa kuti malo oyandikana nawo azioneka bwino.
Chitetezo cha Anthu Onse:Kabati yachitsulo yotsekedwa bwino komanso yolimba imawateteza kwambiri kuti asakhudzidwe ndi anthu mwangozi.
- Zoyipa:
Mtengo Wokwera:Mtengo wake ndi wokwera kwambiri chifukwa cha mtengo wokonza ngalande, mseu, ndi transformer yokha.
Kukonza Mochedwa:Kupeza ndi kukonza zolakwika m'mizere ya pansi pa nthaka kungakhale kotenga nthawi yambiri komanso kowononga (kumafuna kukumba).
Kusatetezeka ku kusefukira kwa madzi:Iyenera kuyikidwa m'malo omwe madzi samatha kusefukira, kapena yokonzedwa mwapadera.
Chidule: Kusiyana Kwakukulu
Kusankha pakati pa ma transformer omangiriridwa ndi ndodo ndi ma pad-mounted sikutanthauza kuti imodzi ikhale "yabwino" kuposa inayo mu vacuum. Ndi za kapangidwe ka makina amagetsi:
Ma transformer okhala ndi mipiringidzo ndi a mizere yopita pamwamba.
Ma transformer omangiriridwa ndi Pad ndi a mizere yapansi panthaka.
Kusiyana kwakukulu kumeneku pakugwiritsa ntchito kumatanthauza kapangidwe kake, malo ake, mtengo wake, ndi ubwino/zoyipa zomwe aliyense amabweretsa pa gridi yamagetsi.