Transformer Yokwera PamwambaMa PMT (PMTs) ndi ngwazi zosayamikirika za kugawa magetsi kwamakono. Monga zigawo zofunika kwambiri pa maukonde amagetsi akumatauni ndi m'mizinda, mayunitsi ang'onoang'ono awa, omwe ali pansi, amapereka magetsi mosamala m'nyumba, m'mabizinesi, komanso m'nyumba zogwirira ntchito za anthu onse. Koma n'chiyani kwenikweni chimawapangitsa kukhala ofunikira kwambiri?
Kutanthauzira Ma Transformers Okwera Pamwamba
Transformer yokhazikika pa pad ndi yotsekedwa, yokhazikika pansi Chosinthira Chogawa Magetsi Yoyikidwa pa simenti. Yopangidwira kugwiritsidwa ntchito panja, imachepetsa magetsi amphamvu (nthawi zambiri 15kV-35kV) kukhala otsika mphamvu (120V-600V) kwa ogwiritsa ntchito.
Zigawo Zofunika:
Thanki ndi Malo Oyikiramo
Nyumba yachitsulo yosagwedezeka ndi mphepo yokhala ndi maloko osagwedezeka ndi mphepo
Zophimba zoteteza dzimbiri kwa zaka zoposa 30
Core & Windings
Zitsulo za silicone zokhala ndi zozungulira zamkuwa/zoluminiyamu
Dongosolo Loziziritsa
Mapangidwe oziziritsidwa ndi convection (OA) kapena okakamizidwa ndi mpweya (FA)
Zitsamba
Kapangidwe koyambirira koteteza bwino
Machitidwe Oteteza
Zipangizo zothandizira kupanikizika, zizindikiro zolakwika, zoletsa kuthamanga kwa magazi
N’chifukwa Chiyani Muyenera Kusankha Ma Transformer Okhala ndi Pad? Ubwino 5 Wofunika Kwambiri
① Kapangidwe Kosungira Malo
Ndi maulumikizidwe a chingwe cha pansi pa nthaka ndi mapazi opapatiza (nthawi zambiri 1.5mx 2m), ma PMT amachotsa kufunikira kwa mizere ndi zipilala zapamwamba - zabwino kwambiri m'madera olemera a m'matauni komanso malo omwe amakhudzidwa ndi kukongola.
② Chitetezo cha Anthu Chowonjezereka
Malo otsekedwa amaletsa kulowa kosaloledwa
Makina osungira mafuta omwe ali m'madzi amakwaniritsa zofunikira za EPA
Chitetezo cha magetsi olakwika chimachepetsa chiopsezo cha moto
③ Ndalama Zochepetsera Zokonzera
Ndi matanki otsekedwa bwino komanso oteteza chinyezi, ma PMT amakono amafunika kukonza kochepera 50% kuposa ma pole-top units kutengera miyezo ya IEEE C57.12.00.
④ Kudalirika kwa Gridi
Ma transformer oikidwa pa Pad amathandizira kukonza ma loop feed - ngati chipangizo chimodzi chalephera, ma network switch okha amasinthira magetsi kuti achepetse kuzima.
⑤ Kusintha Kosinthika
Imapezeka mu mawonekedwe a gawo limodzi (25-500kVA) ndi magawo atatu (75-5,000kVA) ndi zosankha za:
Kuchepetsa mphamvu ya Harmonic
Mapangidwe a phokoso lochepa (
Ma model ogwira ntchito bwino kwambiri (okwaniritsa miyezo ya DOE 2023)
Mapulogalamu: Kumene Pad Mounters Power Communities
Kugawa magawo ndi chitukuko cha nyumba
Malo ogulitsira zinthu ndi malo ogulitsira zinthu
Zipatala ndi mayunivesite
Mapaki a mafakitale (okhala ndi chitetezo cha arc flash)
Kulumikizana kwa mphamvu zongowonjezwdwanso