Chosinthira cha Aloyi Chosasinthikas, chifukwa cha kutayika kwawo kochepa kwambiri komanso kugwiritsa ntchito mphamvu zambiri, zayamba kukhala njira zatsopano zosinthira ma transformer achitsulo cha silicon. Nkhaniyi ikufotokoza mfundo zawo zaukadaulo, ubwino, ntchito, ndi kugwiritsa ntchito mfundo motsogozedwa ndi mfundo kuti zitsogolere kupanga zisankho mwanzeru.
Ine.Osinthira Aloyi Amofous: Tanthauzo ndi Ukadaulo
1Zatsopano pa Zinthu Zakuthupi
u Ntchito yaikuluriboni zachitsulo zopanda mawonekedwe achitsulo(Kukhuthala kwa 0.02-0.04mm) komwe kumapangidwa kudzera mu kuziziritsa kwachangu kwambiri. Kapangidwe kawo ka atomu kosokonezeka (kofanana ndi galasi) kamachotsa kutayika kwa malire a tirigu, ndikuwonjezera mphamvu ya maginito ndi 40-60% kuposa chitsulo cha silicon.
2Kapangidwe ka Kapangidwe
muChimake:Kapangidwe ka miyendo isanu ya magawo atatu kamachepetsa ma harmonics achitatu ndikuwonjezera kukana kwafupikitsa ndi 30%.
muMa windings:Epoxy resin vacuum casting (Class H insulation, 180°C rating), yolimba ku chinyezi, kupopera mchere, ndi nkhungu.
muKuziziritsa:Thanki yotsekedwa yokhala ndi corrugated yokhala ndi kuziziritsa kwachilengedwe (AN) kapena kukakamizidwa mpweya (AF), yomwe imathandizira mphamvu yodzaza ndi 150%.
II.Ubwino 5 Waukulu wa Amorphous Alloy Transformers
1.Kutayika Kotsika Kwambiri, Kusunga Kotsimikizika
lKutaya kosanyamula katundu ndi 70-80% kotsika:Kukana kwa aloyi ya amorphous ndi kwakukulu ka 3-6 kuposa chitsulo cha silicon. Chitsanzo: 10kV/400kVA transformer ya amorphous yopanda katundu = 215W poyerekeza ndi 570W ya chitsulo cha silicon.
lTCO Yotsika:Ngakhale kuti ndalama zomwe mumawononga pasadakhale ndi 30% yokwera, ndalama zomwe mumasunga pachaka zokwana $7,000+ zimabweza ndalamazo kwa zaka 3-5.
2.Kugwirizana Kosawononga Chilengedwe, Kopanda Mpweya
lKuchepetsa CO₂:Matani 5-8 pachaka pa unit; SO₂ yachepetsedwa ndi matani 0.1.
lMoyo wokhazikika:Mafuta okwana 1L amasungidwa pa kilogalamu imodzi ya alloy yopangidwa; 100% cores yobwezerezedwanso.
3.Kudalirika Kwambiri M'mikhalidwe Yovuta
lKulekerera kwa Harmonic:Mitundu ya SCRBH15 imagwira ntchito bwino pansi pa THD ≤5% (yabwino kwambiri kwa ma inverter a PV/VFD).
lChitetezo cholimba:IP23-yovomerezeka pakati pa -40°C ndi +45°C, chinyezi cha 100%.
4.Moyo wa Zaka 30 ndi Wopanda Kukonza
lKukalamba pang'onopang'ono kwa kutentha:1/3 kuchuluka kwa kuwonongeka kwa chitsulo cha silicon.
lKapangidwe kopanda mafuta:Amachotsa kutuluka kwa madzi; Kuwunika kutentha kwa IoT.
5.Zolimbikitsa za Ndondomeko
lKutha kwa gawo lofunikira:China isiya ntchito ma transformer a S7 pofika chaka cha 2025; ≥80% ya gawo la msika la ma model ogwira ntchito bwino kwambiri.
lNdalama zothandizira:Kuchotsera kwa 10% kwa zitsanzo za magwiridwe antchito a Gulu 1 m'maboma angapo.
III.Mapulogalamu Ofunika & Mtengo wa Ogwiritsa Ntchito
1.Mphamvu Zongowonjezedwanso
lKukwera kwa dzuwa/mphepo:Famu ya Ningxia ya mphamvu ya dzuwa ya 2GW yapulumutsa ¥1.2M/chaka kudzera
l yachepetsa kutayika kwa katundu usiku.
lKusunga mphamvu:Imapirira nthawi zambiri zolipirira/kutulutsa mphamvu.
2.Ma Gridi a Mizinda
lMalo ochitira malonda:Shanghai mall yapeza phindu la 18% pogwiritsa ntchito ma transformer a SCBH15.
lMachitidwe a Metro:Mzere wa Guangzhou 18 umagwiritsa ntchito mitundu youma yosapsa ndi moto kuti ikhale yotetezeka pansi pa nthaka.
3.Kugwiritsa Ntchito Mafakitale
lMafakitale achitsulo:Imathandizira kukwera kwa ng'anjo ya arc, ndikusunga ¥500,000 pachaka.
lMalo oyeretsera mafuta:Magalimoto osaphulika amatsimikizira kuti akugwira ntchito bwino ku Xinjiang kwa zaka zoposa 5.
IV.Makhalidwe ndi Malangizo Osankha
1.Mapu a Ukadaulo
lKuwunika mwanzeru:Machitidwe apaintaneti a DGA (≥95% kulondola kwa kulosera zolakwika).
Zinthu zatsopano:Nanocrystalline cores kuchepetsa kutayika ndi 30% (zamalonda pofika chaka cha 2025).
2.Malamulo Osankha
(1)Mafanizo a zotsitsa:Konzani zinthu zosaoneka bwino pa zinthu zotsika mtengo (kuchaja kwa EV); chitsulo cha silicon pa zinthu zotsika mtengo (malo osungira deta).
(2)Werengerani TCO:Amorphous imapereka ndalama zotsika ndi 25-30% pazaka 20 (kugula + mphamvu + kukonza).
(3)Tsimikizani ziphaso:Funsani malipoti a mayeso a CTI/STL kuti mudziwe kuchuluka kwa kutentha komanso mayeso afupikitsa nthawi yoyeserera.
Mapeto
Ma transformer a alloy a Amorphous akutsogolera pamsika ndikusunga mphamvu,kukhazikika,ndi kudalirika, kuyendetsa bwino ntchito yokonza ma gridi ndi kukweza mafakitale. Gawo lawo la msika padziko lonse lapansi likuyembekezeka kukula kuchokera pa 26.8% (2023) mpaka 35% pofika chaka cha 2026. Gwirizanitsani zomwe mwasankha ndi mapatani a katundu ndi ndalama zothandizira kuti muwonjezere phindu la ROI.