+86 18068001229 Kuyerekeza kwaukadaulo: Transformer Yodzipatula vs Transformer Yachizolowezi
- Zolinga Zazikulu Zogwirira Ntchito
Transformers Zachizolowezi
Chopangidwa makamaka kuti chizisintha ma voltage (kukwera/kutsika), ndi chiŵerengero chosafanana cha ma turns pakati pa ma windings oyambira/achiwiri. Cholinga chawo chachikulu ndikusintha ma voltage a AC kuti akwaniritse zofunikira pa katundu.
Yang'anani kwambiri pa galvanic isolation m'malo mosintha magetsi. Ngakhale kuti mitundu ina imasunga chiŵerengero cha 1:1 cha kutembenuka, ntchito yawo yofunika kwambiri ndikuswa njira zamagetsi mwachindunji pakati pa gwero ndi katundu kuti zitsimikizire chitetezo.
- Filosofi Yopanga
Transformers Zachizolowezi
Yopangidwa ndi maginito olumikizira zomwe zimathandiza kusintha kwa magetsi. Ma Autotransformer (gulu laling'ono) amagawana ma windings kuti apange kapangidwe kakang'ono koma alibe mphamvu zodzipatula.
Zosinthira Zodzipatula
Ili ndi zotchingira ziwiri zozungulira ndi zotchingira zamagetsi. Mitundu yapamwamba imaphatikizapo zitseko za Faraday kuti zichepetse phokoso la common-mode ndi transients.
- Zofunikira pa Chitetezo
| Chizindikiro | Transformer Wamba | Chosinthira Chodzipatula |
| Mphamvu ya Dielectric | 1,000V (yachizolowezi) | ≥1,500V (IEC 61558-1 ikugwirizana ndi malamulo) |
| Kutayikira kwamakono | Kufikira 3.5mA |
|
| Kapangidwe ka Pansi | Osalowerera ndale | Malo oyandama kapena nthaka yosankhidwa |
- Zochitika Zogwiritsira Ntchito
Transformers Zachizolowezi
Machitidwe owongolera zochita zokha zamafakitale
Cholinga chachikulu Kugawa Mphamvu (monga, kusintha kwa 380V→220V)
Mapulogalamu ofunikira pamtengo wotsika popanda zofunikira zokhwima zachitetezo
Zosinthira Zodzipatula
Zipangizo zojambulira zithunzi zachipatala (zojambulira za MRI/CT)
Zipangizo zochitira kafukufuku wa zasayansi ndi makina amawu/kanema
Ma interface a mphamvu zongowonjezedwanso (ma inverters a dzuwa)
- Kugwiritsa Ntchito Zaukadaulo
Machitidwe Ogwiritsira Ntchito Ma Wiring
Wamba: Kulumikizana mwachindunji ndi gawo losalowerera
Kupatula: Mizere ya PE/N yodzipereka yokhala ndi kuwunika kwa insulation
Magwiridwe antchito a EMI
Wamba: Amakhudzidwa ndi phokoso loyendetsedwa (50/60Hz harmonics)
Kupatula: >60dB common-mode rejection ratio (CMRR)
- Miyezo Yotsatira Malamulo
Zachizolowezi: IEC 60726-2 (ntchito zamafakitale)
Kupatula: IEC 61558-1/2 (makina ofunikira kwambiri pachitetezo), UL 1950 (zipangizo zachipatala)
Kuyerekeza kokonzedwa kumeneku kukuwonetsa momwe ma transformer odzipatula amaperekera ubwino wofunikira wachitetezo kudzera muukadaulo wapamwamba woteteza kutentha ndi kuletsa phokoso, pomwe ma transformer wamba amaika patsogolo kusintha kwa magetsi kotsika mtengo. Kusankha kumadalira zofunikira zinazake zachitetezo chamagetsi ndi malo ogwirira ntchito.