+86 18068001229 Mkati mwa JZP's Three-Phase Pad-Mounted Transformer: Kuphunzira Kwambiri Zatsopano za Smart Grid

Mu kusintha kwa ukadaulo wa gridi yanzeru, ma transformer a JZP okhala ndi magawo atatu (PMTs) atuluka ngati njira yosinthira zinthu kuti zinthu ziyende bwino. Kugawa MphamvuKuphatikiza kapangidwe kakang'ono ndi uinjiniya wamakono, "ma hub amphamvu anzeru" awa amatanthauzanso kudalirika komanso kukhazikika. Tiyeni tifufuze kapangidwe kake kovuta ka ma PMT a JZP ndikupeza zodabwitsa zaukadaulo zomwe zimalimbikitsa zomangamanga zamakono.
1. Kapangidwe ka Modular: Selo Yamphamvu Yanzeru
Ma PMT a JZP amagwiritsa ntchito kapangidwe ka "SmartCube" komwe kamaphatikiza machitidwe atatu ofunikira kukhala mpanda umodzi, wosagwedezeka ndi nyengo:
Chipinda Chokhala ndi Mphamvu Yaikulu: Ma switch oletsa kutsekeka kwa magetsi otsekedwa ndi vacuum okhala ndi SF6 gas insulation
Choyambira cha Transformer: Choyambira chapamwamba cha aloyi chopanda mawonekedwe chochepetsa kutayika kwa mphamvu
Kugawa kwa Voltage Yotsika: Olamulira a logic omwe angakonzedwe ndi kulumikizana kwa IoT
Kapangidwe kameneka kamachepetsa nthawi yoyika ndi 60% poyerekeza ndi malo osinthira akale ndipo kamatenga malo ocheperako ndi 40%.
2. Makina Okhala ndi Mphamvu Yaikulu: Uinjiniya Woyamba wa Chitetezo
2.1 Njira Yotetezera Yosakanizidwa
Cholepheretsa Vacuum: Choyesedwa pa 63kA short-circuit current yokhala ndi ntchito 10,000 zamakaniko
Mafuse Ozindikira Zinthu Ziwiri: Kuwunika kutentha + mphamvu yamagetsi kuti mutetezedwe
Kulumikizana kwa Makina: Kumaletsa mphamvu mwangozi panthawi yokonza
2.2 Mabatani Anzeru
Zoteteza mpweya za polymer: Zimapirira mphamvu ya 100kV/m
Kulemba kwa RFID: Kumathandizira kuyang'anira matenda osavulaza
Kudziyeretsa Kokha: Kumachepetsa kuzima kwa madzi chifukwa cha kuipitsidwa ndi 75%
3. Choyambira cha Transformer: Magnetic Mastery
3.1 Ukadaulo wa Aloyi Wopanda Maonekedwe
| Chizindikiro | Kufotokozera kwa JZP | Muyezo wa Makampani |
| Kutaya kwapakati (W/kg) | ≤0.12 @50Hz | 0.35 |
| Kuchuluka kwa Maginito | 1.45T | 1.5T |
| Mulingo wa Phokoso | ≤45dB(A) | ≤55dB(A) |
Kapangidwe ka 3ple-legs stacked core kamachepetsa kutayika kwa eddy current ndi 40% kudzera munjira zabwino zosinthira mphamvu
3.2 Matrix Yoziziritsira Yogwira Ntchito
Zigawo za Zinthu Zosinthira Gawo (PCM): Zimayamwa kutentha kwa 300kJ/m³
Zipsepse Zoyambitsa Vortex: Zimawonjezera mphamvu yachilengedwe ya convection ndi 250%
Njira Zoziziritsira Zosakanikirana: Sinthani yokha pakati pa convection/radiation kutengera katundu
4. Dongosolo Lotsika la Voltage: Luntha Lolumikizana ndi Grid
Mphamvu Yowongolera Mphamvu
Chipukuta misozi cha VAR Chosinthika: Chimasunga PF >0.98 pamikhalidwe yonse yonyamula katundu
Kuchepetsa Harmonic: Fyuluta yogwira ntchito ya 4th-order imaletsa ma harmonics a 25th
Kuteteza Kusowa kwa Dera: Kusamutsa mosavuta ku UPS mu
5. Phukusi Lolimbana ndi Zachilengedwe
5.1 Chitetezo cha Gulu Lankhondo
Kuchuluka kwa IP68/IP69K: Kupulumuka kumizidwa m'madzi okwana mamita awiri kwa mphindi 30
Kukana Nkhungu ya Mchere: Kupambana mayeso a ASTM B117 a maola 1000
Kuteteza kwa EMI: 5.2 Zinthu Zosamalira Chilengedwe
Madzi Osungunuka a Dielectric: 100% ester yochokera ku zomera
Chophimba cha Aluminium Chobwezerezedwanso: 98% zipangizo zomwe zingapezekenso
Kapangidwe ka Kutayikira kwa Mafuta Osapitirira Mphindi: Kumagwiritsa ntchito kuletsa nayitrogeni wopanikizika
6. Zinthu Zogwirizanitsa Ma Gridi Anzeru
Chiyanjano cha Distributed Energy Resource (DER): Chimathandizira kuphatikiza kwa solar PV/Storage
Kubwezeretsa Mphamvu ya Voltage (DVR): Kumasunga kukhazikika kwa volteji ya ±1%
Chipata Choyankhira Zofunikira: Chimatenga nawo mbali m'misika yothandizira ntchito zina
Nkhani Zopambana za Ntchito
Ma Microgrid Amakono: Kupereka mphamvu ku nyumba zoposa 15,000 mumzinda wokhazikika wa Dubai
Mayankho a Data Center: 99.999% nthawi yogwira ntchito pa malo a AWS ku Singapore
Kukhazikitsa Magetsi pa Njanji: Kusintha kwa 25kV AC/DC pa sitima za 300km/h
Lumikizanani ndi JZP Lero
Konzani Tsogolo Lanu la Mphamvu ndi Mayankho Anzeru Osinthira Mphamvu
Thandizo laukadaulo: +86 16655239333
Mafotokozedwe onse aukadaulo akutsatira miyezo ya IEC 60076-11 ndi UL 1561.
Kulimbikitsa gridi ya mawa lero - JZP Power Solutions