+86 18068001229 Ubwino ndi kuipa kwa ma transformer odzazidwa ndi mafuta

Ubwino
1.Kuzizira Kwambiri ndi Kutaya Kutentha
Transformer Yomizidwa ndi MafutaGwiritsani ntchito mafuta oteteza kutentha kuti azitha kuyamwa ndi kusamutsa kutentha bwino. Mphamvu yayikulu ya kutentha kwa mafuta komanso mphamvu ya kutentha zimathandiza kuti mafuta azigwira ntchito bwino akamalemera kwambiri, zomwe zimapangitsa kuti azikhala abwino kwambiri pakugwiritsa ntchito mphamvu yamagetsi ambiri.
2.Katundu Wabwino Kwambiri Woteteza Kuteteza
Mafuta a transformer amagwira ntchito ngati njira yolimba yoyeretsera magetsi, kuteteza kuwonongeka kwa magetsi ndi ma circuit afupi. Amalowa mu zinthu zotetezera kutentha monga pepala, kulimbitsa kulimba kwawo ndikuwonjezera moyo wa transformer.
3.Kugwiritsa Ntchito Ndalama Moyenera
Ndalama zoyambira zopangira ndizotsika poyerekeza ndi Transformer Youmas, ndipo ndalama zogwirira ntchito zimachokera ku magwiridwe antchito apamwamba (98–99%) komanso kuchepa kwa mphamvu zomwe zimatayika. Ndalama zokonzera zimatha kuyendetsedwa ndi njira zokhazikika monga kuyesa mafuta ndi kusefa.
4.Kutha Kunyamula Zinthu Zambiri Kwambiri
Kuchuluka kwa kutentha kwa mafuta kumalola kudzaza kwakanthawi popanda kukwera kwakukulu kwa kutentha, zomwe zimapangitsa kuti ma transformer awa akhale oyenera kusinthasintha kwa katundu wamafakitale.
5.Moyo Wautali wa Utumiki
Ngati akusamalidwa bwino, ma transformer oviikidwa mu mafuta amatha kugwira ntchito modalirika kwa zaka 20-40. Mphamvu ya mafutawa yodzichiritsa yokha (monga kupanga mpweya panthawi yozindikira zolakwika) imawonjezera kulimba.
Zoyipa
1.Zoopsa za Moto ndi Kuphulika kwa Mphepo
Mafuta a mchere amakhala ndi mphamvu yoyaka ya ~140°C, zomwe zimapangitsa kuti pakhale ngozi pamoto panthawi yamavuto. Ma firewall ndi makina osungira mafuta ndizofunikira, zomwe zimapangitsa kuti kuyika kwake kukhale kovuta.
2.Nkhawa Zachilengedwe
Kutuluka kwa mafuta kumatha kuipitsa nthaka ndi madzi, zomwe zimafuna kutseka mwamphamvu komanso njira zapadera zotayira. Mafuta opangidwa ndi ester ndi otetezeka koma okwera mtengo kwambiri.
3.Zofunikira pa Kukonza
Kuwunika mafuta nthawi zonse, kuyezetsa chinyezi, ndi kusanthula mpweya (monga kusanthula mpweya wosungunuka) ndikofunikira. Mafuta okalamba amafunika kusinthidwa kapena kusefedwa.
4.Kulemera ndi Kulemera
Matanki amafuta ndi makina oziziritsira mafuta zimapangitsa ma transformer awa kukhala akulu komanso olemera, zomwe zimapangitsa kuti asamagwiritsidwe ntchito m'malo okhala ndi malo ochepa monga nyumba za m'mizinda.
5.Mavuto a Nyengo Yozizira
Pa kutentha kochepa, kukhuthala kwa mafuta kumawonjezeka, zomwe zimapangitsa kuti kutentha kusayende bwino. Mafuta ochokera ku silikoni angafunike, zomwe zimawonjezera ndalama zogwirira ntchito.
Kuyerekeza ndi Ma Transformers Ouma
- Kuchita bwino: Ma transformer odzazidwa ndi mafuta amagwira ntchito bwino kuposa mitundu youma chifukwa cha kuzizira kwambiri komanso kutayika kwa mphamvu kochepa.
- ChitetezoMitundu youma ndi yolimba ndipo ndi yoyenera kugwiritsidwa ntchito m'nyumba/m'mizinda koma siigwira ntchito bwino komanso imakhala yokwera mtengo kwa nthawi yayitali.
- Mapulogalamu: Ma transformer odzazidwa ndi mafuta ndi omwe amalamulira ma gridi amagetsi ndi mafakitale, pomwe mitundu youma ndi yomwe imakondedwa m'malo ovuta.
Mapeto
Ma transformer odzazidwa ndi mafuta amachita bwino kwambirintchito zamphamvu kwambiri, zamagetsi amphamvu kwambirichifukwa cha kugwira ntchito bwino, kulimba, komanso kugwiritsa ntchito bwino ndalama. Komabe, mavuto monga zoopsa za moto ndi kuwononga chilengedwe amafunika kuchepetsedwa kudzera mu njira zodzitetezera zapamwamba komanso kugwiritsa ntchito mafuta opangidwa. Kwa madera omwe ali ndi malo ochepa kapena omwe sakhudzidwa ndi chilengedwe, ma transformer amtundu wouma amapereka njira ina yabwino ngakhale kuti ndalama zambiri zimaperekedwa pasadakhale.